Schréder Australia Pty Ltd Bldg 4A, Parklands Estate, 21-23 South Street, Rydalmere, NSW 2116, Australia T: 1300 489 780 | ABN 17 604 331 937 www.sylvania-schreder.com

Mounting Instructions for BUILT-IN Drivers Both HORIZONTAL and VERTICAL mounting is acceptable. If condensation is likely to occur, vertical mounting is preferred. When vertically mounting, the cable termination must always be at the bottom. When mounting the driver indoors use the below diagram as a guide for minimum spacing. For cabinet mounting guidelines contact Sylvania- Schreder for details. There are further guidelines in the preceding detailed Installation Instructions. Importantly these instructions are a guide only and the installer must ensure there is adequate airflow so that the “ta” rating stated in this specification is not exceeded. Refer to drawing below for “tc” location. To maintain optimum surge withstand capability, the input, output and dim cables ideally should be segregated as much as possible. A distance of even 10mm is adequate. If multiple drivers are located in the same pole or cabinet, it is acceptable to cable tie or group all of the outputs together but separated from the inputs which also can be grouped. See dimensions and mounting bracket details on following pages.

Solid Roof

(minimum)

300mm

UP

EEEEEEEEEEEEEEEEEEEE

200mm (minimum)

IMPORTANT! Not user repairable. Do not remove covers or warranty may be voided.

Cables must be secured using cable ties provided

Terminal block orientation is adjustable. Refer to seperate page for instructions

If terminations on drivers are difficult to reach inside the pole, the installer can pre-fit short cables to the driver with J/Box on the ends before installing in the pole so that termination can be performed in more convienient location.

10mm

Tc 80 °C

CL

* Refer to Installation Instructions for "Thermal Consideration" Mounting plate drilling position for panel 380 x 900 Driver Position Code: Driver through Door 1 (D1), Driver on Bottom (B) & Driver on Top (T). ( Eg. First bottom driver through door 1: D1.B1)

Hook the driver D1.T1, D1.T2 & D3.T1 on mounting plate by using the Bracket Provided (Screw the mounting Bracket to the bottom holes as shown)

Lifting Point

D1.T1

D3.T1

D1.T2

Use the key holes to mount units D1.B1, D1.B2, D2.B1, D2.B2 & D3.B1 on mounting plate by using the Bracket Provided.

D2.B2

D2.B1

87.5

205

(Screw the mounting Bracket to the Top holes as shown)

900

Note : Not all 3 holes in each set are necessary as single large bolt can be used in tapped centre hole or only 2 smaller screws in outer holes.

844

D3.B1

D1.B1

D1.B2

466

380