Contract within the Australian Consumer Law then but not otherwise;- (a) the Company is not liable in tort for any loss or damage suffered by the customer or by any third party; and (b) in no circumstances is Sylvania Schréder liable to the customer or to any third party for any loss of profits, loss of anticipated savings, economic loss or interruption of business or for any indirect or consequential loss (Consequential Loss). Terms of Sale – these Warranty provisions are in substitution for any inconsistent provisions in the Sylvania Schréder Terms and Conditions of Sale in so far as they apply to the Warranty component Raptor Inrush Current
Codes: (IP65) SR4HERWP0IT, (IP65) SR4HERWP01TDP (BUILT-IN) SR4HERGT01TG2, (BUILT-IN) SR4HERGT01TDP 240V (Nominal Mains) I peak = 59A Duration @ 50% of peak 5ms
Earth Leakage Current - 0.2mA per unit Breaker Recommendations (240V)
Codes: (IP65) SR4HERWP0IT, (BUILT-IN) SR4HERGT01TG2 415V (Nominal Mains) I peak = 42.5A Duration @ 50% of peak 5ms
Earth Leakage Current - 0.2mA per unit Breaker Recommendations (415V)
The Drivers are not user repairable. Under no circumstances should any covers on the BUILT-IN driver be removed to access internal components. For IP65 drivers, only the single M8 latch bolt on the main enclosure should be loosened to access the main terminal block. The small diecast box on top of the IP65 driver should not be opened and has tamper proof seals over the lid screw heads. If covers are removed performance could be adversely affected and warranty may be voided. If checking and testing is required, it should only be undertaken by suitably qualified persons and under guidance from Ultra-Tech Electronics technical staff. Fault finding information is available on request (refer to DAT07304)..The main supply should be isolated and locked out before accessing terminals or performing any work near the driver terminations. Although the drivers have various shutdown and protection systems, there may be a residual voltage at the output terminals for a period of time after the main supply has been isolated or after open circuit protection has been activated (less than 50V within 1minute). The voltage at the output terminals should always be checked and if necessary, allow further time to decay before working on the driver terminations.
Maintenance and Repair