Case Studies
Industrial Plant
Energy Savings
100W MHT
LEDNOVA- MIDI
40% Energy Savings
100%
60% 70W
116W
Luminaire fitted with 100W Metal Halide lamp
LEDNOVA-MIDI 70W
Number of fittings
300
300
Energy used (kW)
34,8
21
Energy saved (kW)
13,8
2,9
ROI period (years)
TCO over 10 years (R)
2 766 959
1 975 536
791 423
Savings over 10 years (R)
Please note: Above calculations are for demonstration purposes, please contact us for detailed energy saving and return of investment calculations.
Highmast installation 400W HID replacement
Energy Savings
400W HPS/T
LEDFLOOD- MAXI
39% Energy Savings
100%
61%
265W
432W
Luminaire fitted with 400W High-Pressure Sodium Lamp
LEDFLOOD-MAXI 160 LED
Luminaire power consumption (W)
432
265
Maintenance factor
0.7
0.8
Eh ave (lux) E min (lux)
8.32
9.83
5.2
2.5
11 925
Total power consumption (W)
19 440
Detail on lighting design comparison available on request.