External Front exploded view
External Front how-to install 1. To remove the stainless-steel plate, unscrew the 4x M5 x 12 T25 torx countersunk head screw. 2. Machine the plate if necessary to mount the device. Take the necessary measures to protect the paint during the machining. 3. Cabling can pass through the middle hole on the stainless-steel plate. Assure that the cables have enough room and are not scraping against the plate. With constant vibration, this could cut the cabling, damage the product, and cause electrical risks. If necessary, make the hole bigger or protect the hole with a grommet. 4. To remove the aluminum HDK protector, untighten 4x M5x20 T25 torx head screws. Do not remove the screws completely, they have anti-loss washers. Do not machine the HDK protector. This part maintains the tightness of the module. 5. Assure the blue gasket remains in place on the body. 6. Pass the device cabling through the grommet / cable gland. 7. Mount the stainless-steel plate with the device onto the HDK protector. 8. Complete all the wiring on the connector gear tray. See cabling section 9. Before mounting the HDK protector with the device, make sure that the gasket is well placed in the groove to provide IP 66 protection. That it is clean and not damaged. 10. Assure all the cabling is within the module and will not be caught between the protector and body.