D
B
L
Figure 1 Dimensions of foundation-hole for surface-mount poles
1.2. Buried GRP poles
Surface-mount poles comes in different lengths and the planting depth of the pole depends on the length and mounting height of the luminaire. Details pertaining to the excavation needed can be seen in the table below:
2 * LEDLUME-MAXI’s
Typical Head Weight and Wind Surface Area
Head weight: 13kg each Windage area: 0.045m 2 each
Pole Height (HT) (m)
MH (m)
D (m)
L&B (m)
H (m)
2.6
2.0
0.6
0.75
0.6
3.1
2.5
0.6
0.75
0.6
3.6
3.0
0.6
0.75
0.6
4.1
3.5
0.6
0.75
0.6
4.6
4.0
0.6
0.75
0.6
5.2
4.5
0.7
0.75
0.6
MH
5.7
5.0
0.7
0.75
0.6
6.3
5.5
0.8
0.75
0.6
HT
6.9
6.0
0.9
0.75
0.6
7.4
6.5
0.9
0.75
0.6
8.0
7.0
1.0
0.9
0.6
8.6
7.5
1.1
0.9
0.6
9.2
8.0
1.2
0.9
0.6
9.8
8.5
1.3
0.9
0.6
10.4
9.0
1.4
0.9
0.6
11.0
9.5
1.5
0.9
0.6
11.6
10.0
1.6
0.9
0.6
D
13.4
11.5
1.9
0.9
0.6
14.0
12.0
2.0
0.9
0.6
Figure 2 Dimensions of buried poles
Table 2 Excavation dimensions for buried GRP poles
17
Powered by FlippingBook