Schréder - ATS 4 - tunnel lighting control system

The Advanced Tunnel System 4 provides an optimum solution for implementing a reliable and powerful tunnel lighting control system.

Advanced Tunnel System 4

1

A TUNNEL LIGHTING CONTROL SYSTEM BASED ON INDUSTRY 4.0 TECHNOLOGIES

LIGHTING

MONITORING

REPORTING

COMMISSIONING

SERVICING

2

BOOST MOBILITY

REDUCE MAINTENANCE

INCREASE SAFETY

MAXIMISE SAVINGS

FOR COMPLETE TUNNEL LIGHTING MANAGEMENT

3

For safe and reliable tunnels

In tunnels, optimal driving conditions are essential. A reliable and robust lighting system is the key element to guarantee tunnel users the visibility and the security they need for a safe and comfortable journey. Jointly developed with Phoenix Contact, the Advanced Tunnel System 4 (ATS 4) is a powerful tunnel lighting control system enabling precise remote dimming and switching of each connected luminaire, based on various tunnel parameter inputs. Take control and create tunnels where motorists feel safe and confident.

4

ATS 4 SOLUTION: MEET ALL YOUR EXPECTATIONS 1 2 3 4 CREATE SAFE ENVIRONMENTS FOR USERS BOOST MOBILITY DESIGN SUSTAINABLE TUNNELS GENERATE SIGNIFICANT TIME AND COST SAVINGS

5

URBAN TUNNEL C H A L L E N G E S

> Speed limit > Traffic density and signals > System maintenance

MOBILITY

> Visibility > Emergencies > Obstacles

SAFETY

> Smog alert > Exhaust gas

AIR QUALITY

Increase ractivness: ATS 4 is connected to a SCADA (Supervisory Control and Data Acquisition) system, capable of providing immediate remote response to help you quickly

manage any unexpected event. Anticipate any event:

ATS 4 can integrate a large selection of lighting scenarios to adapt the light levels to any kind of situation (natural light variations, speed limit, pollution peak). Get connected to your environment: ATS 4 can be connected to various lighting sensors and cameras to permanently adapt the light to indoor and outdoor conditions.

6

MOUNTAIN TUNNELS C H A L L E N G E S

> Sun direction > Glare effect > Black hole effect

LIGHT VARIATIONS

> Wet road > Snow conditions > Road reflection

WEATHER CONDITIONS

> Installation lifetime > Components’ resistance

HARSH ENVIRONMENT

SOLUTIONS

Invest in sustainability: ATS 4 enables precise dimming and switching of each connected luminaire, creating adapted lighting to what is absolutely necessary to ensure safe, comfortable driving conditions, and thus resulting in optimised energy consumption . Save valuable time: The ATS 4 reports and manages any failures or repair activities. It also enables integration of Schréder Tunnel Lighting Calculation Software and Lighting Controls System, leading to unparalleled auto-commissioning and maintenance savings .

7

Your tunnel optimised in every way

The ATS 4 provides an optimum solution to implement a reliable and powerful lighting system in tunnels, no matter what the conditions.

Use any relevant input to define, automate and trigger the most suitable lighting scenarios.

SENSOR AND CAMERA INPUTS

TRAFFIC SPEED

AIR DENSITY

EMERGENCY SCENARIO

TUNNEL CONFIGURATION AND GEOMETRY

ROAD CONDITIONS

8

In the recent years, countries and continents have had to deal with new types of cyber crime, requiring higher levels of security for critical infrastructure. Tunnels are part of those infrastructure. A lighting control system involving a wide range of critical data and functions requires the higher level of security to guarantee your tunnel data a safe journey. That’s why the ATS 4 is built on the innovative Phoenix Contact PLCnext technology, an open automation communication system compliant with the most YOUR DATA ARE GOLD, EXPECT THE MOST SECURE SYSTEM

highly demanding cyber security standards such as the European NIS Directive (Network and Information Security EU 2016/1148) and international standard IEC62443 . The ATS 4 controller is the first control system to fully comply with both regulations and can be used in these applications.

The Advanced Tunnel System 4 benefits from a complete set of toolless smart cables and connectors . This cabling philosophy is part of the complete solution provided by Schréder allowing you to speed up system installation and implementation. The communication cables between the central controller and the luminaires themselves is made via an industrial Bus network, perfectly suited to handle the high demands linked with tunnel control applications . SAVE SIGNIFICANT INSTALLATION TIME

9

TRAFFIC FUNCTIONS

NETWORK INFRASTRUCTURE

ENERGY SUPPLY

UTILITIES

VENTILATION

FIRE DETECTION

SAFETY

10

ATS 4: the most complete tunnel lighting control system

ASSET MANAGEMENT SOLUTION

Modbus cloud/ industrial bus

safety-related data management system Real-time tunnel data analysis Lighting component maintenance management

REPORTS

MAINTENANCE MODULE

XLS FILE FOR PREDICTIONS

UTILITIES

TRAFFIC FUNCTIONS

VENTILATION

The Schréder tunnel solutions are based on the Profinet/ Modbus technical standard for data communication over Industrial Ethernet, designed for collecting data from, and controlling, equipment in industrial systems.

NETWORK INFRASTRUCTURE

FIRE DETECTION

Tunnel Control System (TCS 4/ATS 4) Mapping luminaires Data visualisation Emergency scenarios Luminance sensor reading

ENERGY SUPPLY

SAFETY

TCS 4

Alarm function Customisable

L20 luminance meter

L20 luminance meter Luminance measurement Data reporting to ATS

L20 luminance meter

Lumgate RS422 closed loop device

Light switching and dimming Luminaire failure reports CE and UL compliant

11

ATS 4 DALI: Tunnel lighting control system over a DALI network protocol

Enables coordinated dimming and switching of groups of luminaires for even more savings .

Provides the essential control functions of the ATS 4 in a lean feature set .

Equipped with a fully featured powerful lighting control software . No additional interface is required.

The ideal solution for basic tunnels or interior zones of long tunnels.

OPTIMISED INSTALLATION

STANDARD CABLING The ATS 4 DALI benefits from a complete set of toolless standard cables and quick- on connectors, considerably speeding up cabling and saving valuable time on-site.

The ATS 4 DALI cabinet constantly communicates with the ATS 4 DALI boxes . Equipped with multiple DALI outputs (up to 64), the DALI boxes send commands to or receive data from groups of luminaires. This type of system architecture provides an optimised solution for specific tunnel needs.

12

ASSET MANAGEMENT SOLUTION

REPORTS

MAINTENANCE MODULE

XLS FILE FOR PREDICTIONS

UTILITIES

TRAFFIC FUNCTIONS

VENTILATION

The Schréder tunnel solutions are based on the Profinet/ Modbus technical standard for data communication, designed for collecting data from, and controlling, equipment in industrial systems.

NETWORK INFRASTRUCTURE

FIRE DETECTION

ENERGY SUPPLY

SAFETY

TCS

DALI BOXES

Broadcast commanding Up to 64 DALI drivers 8 DALI masters Standard cabling

13

YOUR TUNNEL YOUR SOLUTION

14

DALI network

Industrial bus communication

COMMUNICATION TYPE

Luminaires/driver box equipped with DALI drivers

Luminaires/driver boxes equipped with Lumgate

INSTALLATION TYPE

Broadcast command (one order per luminaire segment)

Individual control (one order per luminaire)

LIGHTING CONTROL

Group failure indication

Precise failure location

MAINTENANCE

Standard cables

Bus communication cables

CABLE TYPE

Up to 300 m per entire segment Up to 400 m between two devices

MAX. CIRCUIT CABLE LENGTH

Toolless Plug-and-Play system

INSTALLATION

2 to 8 DALI masters per ATS 4 DALI box

240 Lumgates per ATS 4

SYSTEM CAPACITY

Basic tunnels or interior zones

Complex tunnel architectures

IDEAL FOR

15

www.schreder.com

Copyright © Schréder S.A. 2022 - Executive Publisher: Stéphane Halleux - Schréder International Services S.A. - rue de Mons 3 - B-4000 Liège (Belgium) - The information, descriptions and illustrations herein are of only an indicative nature. Due to advanced developments, we may be required to alter the characteristics of our products without notice. As these may present different characteristics according to the requirements of individual countries, we invite you to consult us.

16

Page 1 Page 2 Page 3 Page 4 Page 5 Page 6 Page 7 Page 8 Page 9 Page 10 Page 11 Page 12 Page 13 Page 14 Page 15 Page 16

www.schreder.com

Powered by