Installation Instructions for the OWLET IV ZHAGA.
OWLET IV
ZHAGA Luminaire Controllers
Installation Instructions
DATALIFT Z
MESHNODE Z
QR code to access the online
installation instruction.
IP 66
IK 08
INSTALLATION VIDEO
DOC-0020639 OWLET IV Zhaga-INS-B | 10-2022
www.schreder.com
OWLET IV
ZHAGA Luminaire Controllers
Installation Instructions
DATALIFT Z
MESHNODE Z
QR code to access the online
installation instruction.
IP 66
IK 08
PRODUCT
DATALIFT Z
MESHNODE Z
Ta: -40°C to +65°C -40°F to +149°F Operating voltage: 24 VDC
Ta: -40°C to +65°C -40°F to +149°F Operating voltage: 24 VDC
29.9mm 1.18in
47.8mm 1.88in
79.7mm 3.14in
79.7mm 3.14in
0.13kg 0.29lb
0.08kg 0.18lb
kg lb
kg lb
Grey bottom
Grey bottom with red sticker
4
1
4
1
Not Connected
Not Connected
+24V
+24V
2
3
2
3
DA+
DA- / GND
DA+
DA- / GND
DATALIFT
BEST LOCATION, RATIO & DISTANCE
1 DATALIFT : 10 MESH
DATALIFT
MAX. 500M
MAX. 100M
MESHNODES
DOC-0020639 OWLET IV Zhaga-INS-B | 10-2022
www.schreder.com /3
1
INSTALLATION
Before installation contact Schréder FAE (Field Application Engineer) for support.
3
During installation, ensure correct body position over the luminaire.
1
Q
A
FAE
2
Remove cover from socket.
Turning indications on top of controller.
Align the controller’s larger locking pin with the larger locking slot of the ZHAGA socket, and fit the controller gently into the socket.
4
5
Controller
2
1
ZHAGA Socket
7 The installer is responsible for verifying the installation. MECHANICAL VERIFICATION
6
Pull the controller to check if it is locked
Turn controller clockwise until it locks.
8 Extra barcode labels are supplied with the controller
Example list and map.
Inside pole door
DOC-0020639 OWLET IV Zhaga-INS-B | 10-2022
www.schreder.com /3 2
9
SELF-TEST
Note : the self-test occurs only in the first 5 power cycles after installing the controller.
2
3
1
The controller reduces light to minimum level.
The controller switches OFF the light completely.
When powering on luminaire, the light switches ON to maximum level.
2
3
2
3
1
1
2
3
1
100%
10%
100%
10%
100%
10%
30 seconds
100%
10%
30 seconds
30 seconds
30 seconds
OPTIONAL SENSOR TEST trigger a sensor dectection in the luminaire
Correct Luminaire is ON
Incorrect Luminaire is OFF Built-in LED controller is ON
Correct Light level changes from max to min 5
Incorrect Light level does not change
4
5
5
4
4
5
4
100% 10%
120 minutes
100% 10%
100% 10%
100% 10%
120 minutes
120 minutes
120 minutes
120 minutes
6
After the self-test, the luminaire operates as configured on the CMS platform.
6
6
6
DOC-0020639 OWLET IV Zhaga-INS-B | 10-2022
www.schreder.com /3
3