Osvětlení pro sportoviště

Schréder: správné sportovní osvětlení, které splňuje národní a mezinárodní normy, zaručuje bezpečnost, viditelnost a pohodlí a zároveň omezuje světelné znečištění, aby se zachovala tmavá obloha a dobré vztahy s komunitou.

Sports lighting designs The right light, where, when and how it is needed

Content

04

Key facts and figures

06

06 08

Regulations and standards

Regulations and standards

Your benefits

Schréder solutions for sports facilities

10

12

Footbal l field

10

Outdoor tennis court

18

26 30 36 42 46 50 38

Indoor tennis court

Schréder solutions for your sports facilities

Multi-sports hall

Multi-sports ground

Padel court

Swimming pool

Rugby field

Other sports

A few of our projects

60

52 54

Control solutions

Product overview

A few of our projects 60

2

Cédric Collard Schréder Sports Segment Manager

Our society is evolving and our habits are changing. We are more and more connected and remote working is become more common. But moving and breathing is what makes us human and keep us fit. Physical activity is important and is recommended by the World Health Organisation. It is the best natural way to keep your body and your mind in shape. By practising a sport I can challenge myself and socialise while playing with family, friends and new acquaintances. It helps clear the head and keep the mind sharp so we can succeed in our challenges. Players, whether they play for fun or as a professional, wherever they play, indoor or outdoor and whenever they play, during the day or after work, deserve to do so in the best conditions. LED technology has sufficiently evolved to deliver energy-efficient sports lighting that limits light spill and pollution. Sports lighting can also entertain, creating a fun and exciting atmosphere. A well-designed sports lighting solution will also guarantee sharp, vivid images to capture nice moments on TV when our favourite team is scoring or on our phones when our kids are playing. Staying connected with our body, mind and society in the digital era

3

Key facts and figures The trend is here; grab it or leave it!

72 %

75 %

37.1

Average number of hours an employee works - this represents 7.42 hours per day

Percentage of EU population living in urban areas

Percentage of EU population practicing sports outside working hours

Cost per year, for a population of 10 million people, when half of the population is insufficiently active € 910,000,000

55 %

Number of persons employed in the sports sector in Europe 1,694,100

Average energy savings by replacing HID fixtures with LED floodlights

4

5

Regulations and standards EN 12193 for sports lighting The European committee for standardisation has established a norm for sports lighting applications: the European Standard EN 12193. Its purpose is to enable a good quality sports lighting through recommendations and requirements. For each application, the norm defines:

The minimum level of illuminance (E average in lux [lx]) • Maximise visual perception The minimum level of light uniformity (U 0 ) • Maximise visual comfort The maximum level of glare (GR or R G ) • Minimise discomfort The minimum colour rendering index (CRI or R a ) • Maximise real colour perception

How does it work? For each sport

Areas definition • Principal area (playing area needed for the performance of a certain sport) • Total area (additional safety area outside the principal area) Grid points definition • For measurements and calculations • To ensure that light performances are respected Class definition • Class I = top-level competition (international, national, top level training) • Class II = mid-level competition (regional, local, high level training) • Class III = low-level competition (local, small club, training, school sports)

6

7

Your benefits Best partner for retrofits , new installations and maintenance

Sports clubs

Cities

Energy savings High-quality facilities (attract new members and sponsors) Control solution and data monitoring Generate revenue (extend opening hours, more time spent in the bar & restaurant) Improve branding

Promote healthy and active lifestyles Sustainability, dark sky protection, and light pollution minimised Welcoming space Dynamic image Reduced cost of ownership

Players

Installers

Safety and high visual comfort when playing Boost interactions and atmosphere Improve the experience Heighten emotions Flexibility to play day and night

Easy & fast installation Safe set-up Simple planning and maintenance Futureproof (trouble-free upgrades & software updates) Compliant with regulations and certifications

8

Schréder expertise and LED technology for outstanding sports lighting

RETURN ON INVESTMENT

Low light pollution Avoid disturbing the neighbourhood Dark sky compliant Protect our skies, nature and animals 7 R&D offices around the world Always developing cutting-edge technologies Schréder process Enjoy a personalised service from the audit to the installation and the commissioning SUSTAINABILITY & RELIABILITY

COMFORT

High quantity of light Up to 240,000 lumen per floodlight to enjoy every detail of the game High uniformity Minimum of 70% to avoid dark zones Low glare Maximum of 55 to not disturb players and spectators during the game Instant light Control the luminaires physically via a power switch or remotely via a wireless control system

Low energy consumption Up to 75% energy savings compared with HID lighting power consumption Huge lifetime Above 50,000 hours = 34 years if the luminaires operate 4h per day Versatile control solutions The right light where, when and how it is needed

9

Schréder solutions for sports facilities

12

Football field

18 26

Outdoor tennis court

Indoor tennis court

30

Multi-sports hall

36 38 42 46 50

Multi-sports ground

Padel court

Swimming pool

Rugby field

Other sports

10

s

11

Football field

12

Masts in the corners (before the sideline) Football lighting solutions

105m

Principal area: 105x68m

EN12193 Class I

EN12193 Class II

EN12193 Class III

Grid points: 21x13 = 273pt Number of masts: 4 Masts location: x: 14m / y: -4m Maintenance factor: 0.9

200lx

75lx

ILLUMINANCE 500lx

UNIFORMITY

0.7

0.6

0.5

GLARE

55

55

55

CRI

70

60

60

13

Football field

SOLUTION CLASS I COMPLIANT

1

Nominal values

HID

Professional 500lux – 200lux – 75lux Mast height: 18m

106kW

Illuminance

506lx

Uniformity

0.77

500lux 99%

50% energy saved

53kW

GR

<55

ECOBLAST 6

CRI

70

200lux 40%

80% energy saved

Total power

53,120W

21kW

Total number of floodlights

32

75lux 15%

8kW

92% energy saved

Floodlights per pole

8

Initial flux

236,100lm

Colour temperature

OMNIBLAST GEN2

Other configuration

4000K

Power

1,660W

• technical versatility

SOLUTION CLASS II COMPLIANT

2

Nominal values

HID

Semi-professional 200lux – 100lux – 75lux Mast height: 18m

44kW

Illuminance

211lx

Uniformity

0.80

200lux 95%

43% energy saved

25kW

GR

<55

ECOBLAST 6

CRI

70

100lux 47%

73% energy saved

Total power

26,560W

12kW

Total number of floodlights

16

75lux 36%

10kW

77% energy saved

Floodlights per pole

4

Initial flux

236,100lm

OMNISTAR

Colour temperature

OMNIBLAST GEN2

Other configurations

4000K

Power

1,660W

• technical versatility

• specific

mountings

14

SOLUTION CLASS III COMPLIANT Amateur 100lux – 75lux Mast height: 18m

3

Nominal values

HID

24kW

Illuminance

107lx

Uniformity

0.74

100lux 93%

50% energy saved

12kW

GR

<55

ECOBLAST 6

CRI

70

75lux 70%

63% energy saved

Total power

13,280W

9kW

Total number of floodlights

8

Floodlights per pole

2

Initial flux

236,100lm

OMNISTAR

Colour temperature

OMNIBLAST GEN2

Other configurations

4000K

Power

1,660W

• technical versatility

• specific

mountings

SOLUTION CLASS III COMPLIANT Amateur 75lux Mast height: 18m

4

Nominal values

HID

18kW

Illuminance

88lx

Uniformity

0.74

75lux 85%

50% energy saved

9kW

GR

<55

ECOBLAST 5

CRI

70

Total power

11,080W

Total number of floodlights

8

Floodlights per pole

2

Initial flux

196,800lm

OMNISTAR

Colour temperature

OMNIBLAST GEN2

Other configurations

4000K

Power

1,385W

• technical versatility

• specific

mountings

15

Football field

Masts in the corners (behind the sideline) Football lighting solutions

105m

Principal area: 105x68m

EN12193 Class I

EN12193 Class II

EN12193 Class III

Grid points: 21x13 = 273pt Number of masts: 4 Masts location: x: -6.5m / y: -4m Maintenance factor: 0.9

200lx

75lx

ILLUMINANCE 500lx

UNIFORMITY

0.7

0.6

0.5

GLARE

55

55

55

CRI

70

60

60

16

SOLUTION CLASS I COMPLIANT

5

Nominal values

HID

Professional 500lux – 200lux – 75lux Mast height: 25m

106kW

Illuminance

507lx

Uniformity

0.89

500lux 99%

42% energy saved

62kW

GR

<55

ECOBLAST 6

CRI

70

200lux 39%

76% energy saved

Total power

63,100W

25kW

Total number of floodlights

40

75lux 15%

9kW

92% energy saved

Floodlights per pole

10

Initial flux

236,100lm

OMNIBLAST GEN2

Other configuration

Colour temperature

4000K

Power

1,660W

• technical versatility

SOLUTION CLASS II COMPLIANT

6

Nominal values

HID

Semi-professional 200lux – 100lux – 75lux Mast height: 25m

44kW

Illuminance

223lx

Uniformity

0.83

200lux 90%

32% energy saved

30kW

GR

<55

ECOBLAST 6

CRI

70

100lux 45%

66% energy saved

Total power

33,200W

15kW

Total number of floodlights

20

75lux 34%

11kW

75% energy saved

Floodlights per pole

5

Initial flux

236,100lm

OMNISTAR

Colour temperature

OMNIBLAST GEN2

Other configurations

4000K

Power

1,660W

• technical versatility

• specific

mountings

17

Outdoor tennis court

18

Masts in the corners (before the baseline) Outdoor tennis lighting solutions

23.77m

Principal area: 30x15m Grid points: 13x7 = 91pt Number of masts: 4 Masts location: x: 4m / y: -4m Maintenance factor: 0.9

EN12193 Class I

EN12193 Class II

EN12193 Class III

300lx

200lx

ILLUMINANCE 500lx

UNIFORMITY

0.7

0.7

0.6

GLARE

50

50

55

CRI

70

60

60

19

Outdoor tennis court SOLUTION CLASS I COMPLIANT

1

Nominal values

HID

Professional 500lux – 300lux – 200lux Mast height: 8m

12,320W

Illuminance

530lx

Uniformity

0.80

500lux 94%

71% energy saved

3,609W

GR

<50

INDU FLOOD GEN2 3

CRI

70

300lux 57%

82% energy saved

Total power

3,840W

2,189W

Total number of floodlights

12

200lux 38%

1,459W

88% energy saved

Floodlights per pole

3

Initial flux

58,000lm

OMNISTAR

Colour temperature

OMNIFLOOD

Other configurations

4000K

Power

320W

• technical versatility

• specific

mountings • remote driver

SOLUTION CLASS II COMPLIANT Semi-professional 300lux – 200lux Mast height: 8m

2

Nominal values

HID

4,480W

Illuminance

354lx

Uniformity

0.79

300lux 85%

51% energy saved

2,176W

GR

<50

INDU FLOOD GEN2 3

CRI

70

200lux 56%

68% energy saved

Total power

2,560W

1,433W

Total number of floodlights

8

Floodlights per pole

2

Initial flux

58,000lm

OMNISTAR

OMNIFLOOD

Other configurations

Colour temperature

4000K

Power

320W

• technical versatility

• specific

mountings • remote driver

20

21

Outdoor tennis court

Masts in the corners (behind the baseline) Outdoor tennis lighting solutions

23.77m

Principal area: 30x15m Grid points: 13x7 = 91pt Number of masts: 4 Masts location: x: -6m / y: -4m Maintenance factor: 0.9

EN12193 Class I

EN12193 Class II

EN12193 Class III

300lx

200lx

ILLUMINANCE 500lx

UNIFORMITY

0.7

0.7

0.6

GLARE

50

50

55

CRI

70

60

60

22

SOLUTION CLASS I COMPLIANT

3

Nominal values

HID

Professional 500lux – 300lux – 200lux Mast height: 10m

12,320W

Illuminance

507lx

Uniformity

0.82

500lux 99%

54% energy saved

5,683W

GR

<50

ECOBLAST 6

CRI

70

300lux 59%

73% energy saved

Total power

5,740W

3,387W

Total number of floodlights

4

200lux 39%

2,239W

82% energy saved

Floodlights per pole

1

Initial flux

215,200lm

OMNISTAR

INDUFLOOD GEN2

Other configurations

Colour temperature

4000K

• specific

• higher

Power

1,435W

mountings

lumen/watt

SOLUTION CLASS II COMPLIANT Semi-professional 300lux – 200lux Mast height: 10m

4

Nominal values

HID

4,480W

Illuminance

312lx

Uniformity

0.77

300lux 96%

18% energy saved

3,686W

GR

<50

INDU FLOOD GEN2 3

CRI

70

200lux 64%

45% energy saved

Total power

3,840W

2,458W

Total number of floodlights

12

Floodlights per pole

3

Initial flux

58,000lm

OMNISTAR

OMNIFLOOD

Other configurations

Colour temperature

4000K

Power

320W

• technical versatility

• specific

mountings • remote driver

23

Outdoor tennis court

Masts in the corners (behind the baseline) Outdoor tennis lighting solutions

32.5m

Principal area: 30x15m Grid points: 13x7 = 91pt Number of masts: 4 Masts location: x: 4m / y: -4m Maintenance factor: 0.9

EN12193 Class I

EN12193 Class II

EN12193 Class III

300lx

200lx

ILLUMINANCE 500lx

UNIFORMITY

0.7

0.7

0.6

GLARE

50

50

55

CRI

70

60

60

24

SOLUTION CLASS II COMPLIANT Semi-professional 300lux – 200lux Mast height: 12m

5

Nominal values

HID

10,350W

Illuminance

304lx

Uniformity

0.72

300lux 99%

57% energy saved

4,455W

GR

<50

INDU FLOOD GEN2 3

CRI

70

200lux 66%

71% energy saved

Total power

4,500W

2,970W

Total number of floodlights

12

Floodlights per pole

3

Initial flux

69,600lm

OMNISTAR

OMNIFLOOD

Other configurations

Colour temperature

4000K

Power

375W

• technical versatility

• specific

mountings • remote driver

SOLUTION CLASS III COMPLIANT Amateur 200lux Mast height: 12m

6

Nominal values

HID

5,360W

Illuminance

202lx

Uniformity

0.72

200lux 99%

45% energy saved

2,970W

GR

<55

INDU FLOOD GEN2 3

CRI

70

Total power

3,000W

Total number of floodlights

8

Floodlights per pole

2

Initial flux

69,600lm

OMNISTAR

OMNIFLOOD

Other configurations

Colour temperature

4000K

Power

375W

• technical versatility

• specific

mountings • remote driver

25

Indoor tennis court

26

Bilateral implantation Indoor tennis lighting solutions

23.77m

Principal area: 30x15m Grid points: 13x7 = 91pt Implantation: Bilateral Lateral distance between floodlights and tennis court: 3.5m Floodlights tilt: 5° Maintenance factor: 0.9

EN12193 Class I

EN12193 Class II

EN12193 Class III

500lx

300lx

ILLUMINANCE 750lx

UNIFORMITY

0.7

0.7

0.5

GLARE

35

40

40

CRI

80

60

60

27

Indoor tennis court SOLUTION CLASS I COMPLIANT

1

Nominal values

HID

Professional 750lux – 500lux – 300lux Installation height: 7m

9,240W

Illuminance

789lx

Uniformity

0.76

750lux 95%

49% energy saved

4,739W

GR

<35

INDU FLOOD GEN2 3

CRI

80

500lux 63%

66% energy saved

Total power

4,988W

3,142W

Total number of floodlights

14

300lux 38%

1,895W

79% energy saved

Floodlights per side

7

Initial flux

65,300lm

OMNISTAR

Colour temperature

Other configuration

4000K

Power

375W

• specific

mountings • remote driver

SOLUTION CLASS II COMPLIANT

2

Nominal values

HID

Semi-professional 500lux – 300lux – 200lux Installation height: 7m

6,160W

Illuminance

504lx

Uniformity

0.76

500lux 99%

52% energy saved

2,970W

GR

<40

INDU FLOOD GEN2 3

CRI

70

300lux 60%

71% energy saved

Total power

3,000W

1,800W

Total number of floodlights

8

Floodlights per side

4

Initial flux

69,600lm

OMNISTAR

Other configuration

Colour temperature

4000K

Power

375W

• specific

mountings • remote driver

28

SOLUTION CLASS III COMPLIANT

3

Nominal values

HID

Amateur 300lux – 200lux Installation height: 7m

3,700W

Illuminance

312lx

Uniformity

0.79

300lux 96%

50% energy saved

1,843W

GR

<40

INDU FLOOD GEN2 3

CRI

70

Total power

1,920W

Total number of floodlights

6

Floodlights per side

3

Initial flux

58,000lm

OMNISTAR

Colour temperature

Other configuration

4000K

Power

320W

• specific

mountings • remote driver

29

Multi-sports hall

30

Bilateral implantation Multi-sports hall lighting solutions

40m

Principal area: 40x20m

Grid points: 15x7 = 105pt Implantation: Bilateral Lateral distance between floodlights and field: 1m Floodlights tilt: 20° Maintenance factor: 0.9

EN12193 Class I

EN12193 Class II

EN12193 Class III

500lx

200lx

ILLUMINANCE 750lx

UNIFORMITY

0.7

0.7

0.5

GLARE

35

40

40

CRI

80

60

60

31

Multi-sports hall SOLUTION CLASS I COMPLIANT

1

Nominal values

HID

Professional 750lux – 500lux – 200lux Installation height: 7m

29,250W

Illuminance

772lx

Uniformity

0.73

750lux 97%

70% energy saved

8,730W

GR

<35

INDU FLOOD GEN2 3

CRI

80

500lux 65%

80% energy saved

Total power

9,000W

5,850W

Total number of floodlights

24

200lux 26%

2,340W

92% energy saved

Floodlights per side

12

Initial flux

65,300lm

OMNISTAR

Colour temperature

Other configuration

4000K

Power

375W

• specific

mountings • remote driver

SOLUTION CLASS II COMPLIANT

2

Nominal values

HID

Semi-professional 500lux – 300lux – 200lux Installation height: 7m

19,500W

Illuminance

514lx

Uniformity

0.84

500lux 97%

70% energy saved

5,820W

GR

<40

INDU FLOOD GEN2 3

CRI

70

300lux 58%

Total power

6,000W

82% energy saved

3,480W

Total number of floodlights

16

200lux 39%

88% energy saved

2,340W

Floodlights per side

8

Initial flux

69,600lm

OMNISTAR

Other configuration

Colour temperature

4000K

Power

375W

• specific

mountings • remote driver

32

SOLUTION CLASS III COMPLIANT

3

Nominal values

HID

Amateur 300lux – 200lux Installation height: 7m

11,700W

Illuminance

313lx

Uniformity

0.76

300lux 96%

69% energy saved

3,600W

GR

<40

INDU FLOOD GEN2 3

CRI

70

200lux 64%

79% energy saved

Total power

3,750W

2,400W

Total number of floodlights

10

Floodlights per side

5

Initial flux

69,600lm

OMNISTAR

Colour temperature

Other configuration

4000K

Power

375W

• specific

mountings • remote driver

SOLUTION CLASS III COMPLIANT

4

Nominal values

HID

Amateur 200lux Installation height: 7m

7,800W

Illuminance

207lx

Uniformity

0.80

200lux 97%

68% energy saved

2,483W

GR

<40

INDU FLOOD GEN2 3

CRI

70

Total power

2,560W

Total number of floodlights

8

Floodlights per side

4

Initial flux

58,000lm

OMNISTAR

Other configuration

Colour temperature

4000K

Power

320W

• specific

mountings • remote driver

33

Multi-sports hall

Industrial implantation Multi-sports hall lighting solutions

40m

Principal area: 40x20m

EN12193 Class I

EN12193 Class II

EN12193 Class III

Grid points: 15x7 = 105pt Implantation: Industrial Maintenance factor: 0.9

500lx

200lx

ILLUMINANCE 750lx

UNIFORMITY

0.7

0.7

0.5

GLARE

35

40

40

CRI

80

60

60

34

SOLUTION CLASS II COMPLIANT

5

Nominal values

HID

Semi-professional 500lux – 300lux – 200lux Installation height: 8m

19,500W

Illuminance

558lx

Uniformity

0.87

500lux 90%

77% energy saved

4,554W

GR

<40

INDU BAY GEN3 1

CRI

80

300lux 54%

86% energy saved

Total power

5,060W

2,732W

Total number of high- bays

44

200lux 36%

1,822W

91% energy saved

High-bays implantation

11x4

Initial flux

18,700lm

Colour temperature

4000K

Power

115W

SOLUTION CLASS III COMPLIANT

6

Nominal values

HID

Amateur 200lux Installation height: 8m

7,800W

Illuminance

236lx

Uniformity

0.75

200lux 85%

75% energy saved

1,955W

GR

<40

INDU BAY GEN3 1

CRI

80

Total power

2,300W

Total number of high- bays

20

High-bays implantation

5x4

Initial flux

18,700lm

Colour temperature

4000K

Power

115W

35

Multi-sports ground

Masts in the corners (before the baseline) Multi-sports ground lighting solutions

40m

Principal area: 40x20m

EN12193 Class I

EN12193 Class II

EN12193 Class III

Grid points: 15x7 = 105pt Number of masts: 4 Masts location: x: 8m / y: -3m Maintenance factor: 0.9

200lx

75lx

ILLUMINANCE 500lx

UNIFORMITY

0.7

0.6

0.5

GLARE

55

55

55

CRI

70

60

60

36

SOLUTION CLASS II COMPLIANT Semi-professional 200lux – 75lux Mast height: 8m

7

Nominal values

HID

6,380W

Illuminance

238lx

Uniformity

0.69

200lux 84%

61% energy saved

2,520W

GR

<55

INDU FLOOD GEN2 3

CRI

70

75lux 32%

85% energy saved

Total power

3,000W

960W

Total number of floodlights

8

Floodlights per pole

2

Initial flux

69,600lm

OMNISTAR

OMNIFLOOD

Other configurations

Colour temperature

4000K

Power

375W

• technical versatility

• specific

mountings • remote driver

SOLUTION CLASS III COMPLIANT Amateur 75lux Mast height: 8m

8

Nominal values

HID

3,520W

Illuminance

85lx

Uniformity

0.67

75lux 88%

75% energy saved

880W

GR

<55

INDU FLOOD GEN2 3

CRI

70

Total power

1,000W

Total number of floodlights

4

Floodlights per pole

1

Initial flux

46,400lm

OMNISTAR

OMNIFLOOD

Other configurations

Colour temperature

4000K

Power

250W

• technical versatility

• specific

mountings • remote driver

37

Padel court

38

Masts on / outside the cage Padel lighting solutions

Principal area: 20x10m Grid points: 13x7 = 91pt Number of masts: 4 Masts location: x: 4m / y: 0m Maintenance factor: 0.9

EN12193 Class I

EN12193 Class II

EN12193 Class III

Indoor

EN12193 Class I

EN12193 Class II

EN12193 Class III

Outdoor

500lx

300lx

ILLUMINANCE 750lx

300lx

200lx

ILLUMINANCE 500lx

UNIFORMITY

0.7

0.7

0.5

UNIFORMITY

0.7

0.7

0.6

GLARE

35

40

40

GLARE

50

50

55

CRI

80

60

60

CRI

70

60

60

39

Padel court SOLUTION

1

CLASS I (INDOOR)

Nominal values

HID

Professional 750lux – 500lux – 300lux Mast height: 6m

5,700W

Illuminance

797lx

Uniformity

0.76

750lux 94%

58% energy saved

2,406W

GR

<35

INDU FLOOD GEN2 3

CRI

80

500lux 63%

72% energy saved

Total power

2,560W

1,613W

Total number of floodlights

8

300lux 38%

973W

83% energy saved

Floodlights per pole

2

Initial flux

54,400lm

OMNISTAR

Colour temperature

OMNIFLOOD

Other configurations

4000K

Power

320W

• technical versatility

• specific

mountings • remote driver

SOLUTION

2

CLASS II (INDOOR) CLASS I (OUTDOOR)

Nominal values

HID

Pro & semi-pro 500lux – 300lux – 200lux Mast height: 6m

3,900W

Illuminance

635lx

Uniformity

0.78

500lux 79%

59% energy saved

1,580W

GR

<40

INDU FLOOD GEN2 3

CRI

70

300lux 47%

76% energy saved

Total power

940W

2,000W

Total number of floodlights

8

200lux 31%

620W

84% energy saved

Floodlights per pole

2

Initial flux

46,400lm

OMNISTAR

OMNIFLOOD

Other configurations

Colour temperature

4000K

Power

250W

• technical versatility

• specific

mountings • remote driver

40

SOLUTION

3

CLASS III (INDOOR) CLASS II (OUTDOOR)

Nominal values

HID

Semi-pro & amateur 300lux – 200lux Mast height: 6m

2,000W

Illuminance

318lx

Uniformity

0.78

300lux 94%

53% energy saved

940W

GR

<40

INDU FLOOD GEN2 3

CRI

70

200lux 63%

69% energy saved

Total power

1,000W

630W

Total number of floodlights

4

Floodlights per pole

1

Initial flux

46,400lm

OMNIFLOOD

Other configuration

Colour temperature

4000K

Power

250W

• technical versatility

SOLUTION CLASS III (OUTDOOR) Amateur 200lux Mast height: 6m

4

Nominal values

HID

1,400W

Illuminance

247lx

Uniformity

0.77

200lux 81%

56% energy saved

616W

GR

<55

INDU FLOOD GEN2 3

CRI

70

Total power

760W

Total number of floodlights

4

Floodlights per pole

1

Initial flux

34,800lm

OMNIFLOOD

Other configuration

Colour temperature

4000K

Power

190W

• technical versatility

41

Swimming pool

42

Bilateral implantation Swimming pool lighting solutions

Principal area: 25x15m Grid points: 13x7 = 91pt Implantation: Bilateral Lateral distance between floodlights and pool: 2m Maintenance factor: 0.9

EN12193 Class I

EN12193 Class II

EN12193 Class III

300lx

200lx

ILLUMINANCE 500lx

UNIFORMITY

0.7

0.7

0.5

GLARE

35

40

40

CRI

80

60

60

43

Swimming pool SOLUTION CLASS I COMPLIANT

1

Nominal values

HID

Professional 500lux – 300lux – 200lux Installation height: 7m

6,400W

Illuminance

572lx

Uniformity

0.75

500lux 87%

49% energy saved

3,263W

GR

<35

INDU FLOOD GEN2 3

CRI

80

300lux 52%

70% energy saved

Total power

3,750W

1,950W

Total number of floodlights

10

200lux 35%

1,313W

79% energy saved

Floodlights per side

5

Initial flux

65,300lm

OMNISTAR

Colour temperature

Other configuration

4000K

Power

375W

• specific

mountings • Remote driver

SOLUTION CLASS II COMPLIANT

2

Nominal values

HID

Semi-professional 300lux – 200lux Installation height: 7m

3,900W

Illuminance

313lx

Uniformity

0.79

300lux 96%

51% energy saved

1,920W

GR

<40

INDU FLOOD GEN2 3

CRI

70

200lux 64%

67% energy saved

Total power

1,280W

2,000W

Total number of floodlights

8

Floodlights per side

4

Initial flux

46,400lm

OMNISTAR

Other configuration

Colour temperature

4000K

Power

250W

• specific

mountings • Remote driver

44

SOLUTION CLASS III COMPLIANT

3

Nominal values

HID

Amateur 200lux Installation height: 7m

2,600W

Illuminance

217lx

Uniformity

0.88

200lux 92%

47% energy saved

1,380W

GR

<40

INDU FLOOD GEN2 3

CRI

70

Total power

1,500W

Total number of floodlights

6

Floodlights per side

3

Initial flux

46,400lm

OMNISTAR

Colour temperature

Other configuration

4000K

Power

250W

• specific

mountings • Remote driver

45

Rugby field

46

Masts in the corners (before the dead ball line) Rugby lighting solutions

120m

Principal area: 120x70m

EN12193 Class I

EN12193 Class II

EN12193 Class III

Grid points: 23x11 = 253pt Number of masts: 4 Masts location: x: 14m / y: -4m Maintenance factor: 0.9

200lx

75lx

ILLUMINANCE 500lx

UNIFORMITY

0.7

0.6

0.5

GLARE

55

55

55

CRI

70

60

60

47

Rugby field SOLUTION CLASS I COMPLIANT

1

Nominal values

HID

Professional 500lux – 200lux – 75lux Mast height: 18m

125kW

Illuminance

502lx

Uniformity

0.74

500lux 100%

52% energy saved

60kW

GR

<55

ECOBLAST 6

CRI

70

200lux 40%

81% energy saved

Total power

59,760W

24kW

Total number of floodlights

36

75lux 15%

9kW

93% energy saved

Floodlights per pole

9

Initial flux

236,100lm

Colour temperature

OMNIBLAST GEN2

Other configuration

4000K

Power

1,660W

• technical versatility

SOLUTION CLASS II COMPLIANT

2

Nominal values

HID

Semi-professional 200lux – 100lux – 75lux Mast height: 18m

52kW

Illuminance

201lx

Uniformity

0.78

200lux 100%

50% energy saved

26kW

GR

<55

ECOBLAST 6

CRI

70

100lux 50%

75% energy saved

Total power

26,560W

13kW

Total number of floodlights

16

75lux 37%

10kW

81% energy saved

Floodlights per pole

4

Initial flux

236,100lm

OMNISTAR

Colour temperature

OMNIBLAST GEN2

Other configurations

4000K

Power

1,660W

• technical versatility

• specific

mountings

48

SOLUTION CLASS III COMPLIANT Amateur 75lux Mast height: 18m

3

Nominal values

HID

28kW

Illuminance

82lx

Uniformity

0.70

75lux 91%

64% energy saved

10kW

GR

<55

ECOBLAST 5

CRI

70

Total power

11,080W

Total number of floodlights

8

Floodlights per pole

2

Initial flux

196,800lm

OMNISTAR

Colour temperature

OMNIBLAST GEN2

Other configurations

4000K

Power

1,385W

• technical versatility

• specific

mountings

49

Other sports

Golf

Stadium

Table tennis

BMX

50

Ice Hockey

Athleticism

Firing range

Hockey

51

Control solutions The right light, where , when and how it is needed

Schréder ITERRA

Schréder provides a full range of intelligent control solutions to ensure comfort and an effective energy management. This includes dimming, scheduling, monitoring and the creation of dynamic lighting scenarios to entertain fans. All of our floodlights and luminaires are designed to be controlled wirelessly or via cables in outdoor and indoor environments.

52

Schréder ITERRA

BASIC

CORE

ACTIVE

Flexible, easy & straightforward

V

V

V

Cost-effective

V

V

V

Increased lifetime of luminaires

V

V

V

Easy to install

V

V

V

Easy to manage

V

V

V

Easy to monitor

V

V

V

Scalable & futureproof

V

V

V

Open standards & protocols

V

V

V

Wireless • DALI Bluetooth (BLE5.0 mesh network – up to 200m or Gateway) • DMX

V

V

V

Wired • DALI • DMX

V

V

V

Software trigger

V

V

V

Manual trigger

V

V

V

Scheduling and sensors

V

V

SMS control

V

V

Physical box with code/token

V

V

Complex integration (≠ type of field, outdoor + indoor, wired + wireless)

V

V

Data monitoring

V

V

V

Cloud access

V

V

V

Secured protocols

V

V

V

Dimming

V

V

V

Scenes creation

V

V

V

Custom request

V

V

Entertainment & show

V

RGBW

V

Colour temperature

V

Music synchronisation

V

53

Product overview

1 - 10V DAL I OR DMX

DAL I OR DMX

GLASS IK 09

PC IK 10

IK 08

IP 66

IP 66

ECOBLAST

OMNIBLAST GEN2 OMNIBLAST GEN2 is the ideal tool for sports venues and other large area applications that require a lighting solution with the highest efficiency and flexibility to adapt to the different lighting needs.

ECOBLAST is a new innovative modular floodlight that has been designed to offer an outstanding combination of performance and flexibility for lighting sports venues where high lumen packages and a perfect control of light are needed.

3

4

5

6

1

2

3

Typical luminaire output flux (range)

Typical luminaire output flux (range)

Up to 104,700lm

Up to 139,600lm

Up to 174,500lm

Up to 209,400lm

Up to 64,800lm Up to 105lm/W

Up to 129,700lm Up to 108lm/W

Up to 194,600lm Up to 105lm/W

LM/W

Up to 113lm/W

LM/W

Up to 1,240W

Up to 1,550W

Up to 1,850W

Power consumption Up to 930W

Up to 1,202W

Up to 1,856W

Up to 618W

Power consumption

3000K / 4000K / 5700K

Colour temperature

3000K / 4000K / 5700K

Colour temperature

CRI

70 / 80 / 90

CRI

70 / 80 / 90

Nominal voltage

220-400V / 277V / 347V / 50-60Hz

Nominal voltage

220-400V / 120-277V / 347-480V / 50-60Hz

Ta

Up to 45°C

Ta

Up to 55°C

CxS

Up to 0.297

CxS

Up to 0.554

In-rush current

5A

In-rush current

5A

A

A

C

C

C

C

B

B

A

A

B

B

A

3

4 5

6

1

2

3

C

A 696 mm B 583mm 765mm C 360mm 346mm

595mm 700mm

A

B

188mm 630mm

B

C

A

250mm 520mm 790mm 12kg 28kg 35kg

C

C

*

19kg 24kg 28kg 31kg

54

KG

KG

A

B

B

*Weight without driver

IP 66

IK 08

IP 66

IK 08

OMNIFLOOD

OMNISTAR

OMNIFLOOD is the ideal versatile tool to replace floodlights equipped with traditional discharge lamps of 50 to 400W

OMNISTAR is a versatile LED floodlight that provides a beneficial replacement for a full range of HID lighting fixtures in a variety of indoor and outdoor sports applications.

1

3

MONO

Typical luminaire output flux (range)

Up to 5,300lm

Up to 25,100lm

Typical luminaire output flux (range)

Up to 67,800lm

LM/W

Up to 122lm/W Up to 135lm/W

LM/W

Up to 160lm/W

Up to 53W

Up to 227W

Power consumption

Power consumption

Up to 532W

3000K / 4000K

Colour temperature

Colour temperature

3000K / 4000K / 5700K

CRI

70

CRI

70 / 80 / 90

Nominal voltage

220-240V / 50-60Hz

Nominal voltage

220-400V / 120-277V / 347-480V / 50-60Hz

Up to 55°C

Ta

Ta

Up to 55°C

CxS

Up to 0.349

CxS

Up to 0.260

In-rush current

170A

In-rush current

150A

1

3

B

A

532mm

A

500mm 546mm

A

C

80mm

B

72mm 88mm

B

C

530mm 14kg

C

311mm 475mm 9kg 18.4kg

C

A

KG

KG

B

55

Product overview

GLASS IK 08

PC IK 10

IP 66

IK 09

IP 66

INDU BAY GEN3 With the 3 rd generation INDU BAY GEN3, Schréder offers the leading luminaire for high-bay environments with a minimised total cost of ownership.

INDU FLOOD GEN2 INDU FLOOD GEN2 is an innovative floodlight that combines outstanding lumen output and low consumption. Schréder provides here the leading luminaire in terms of lumen per watt.

1

2

1

2

3

Typical luminaire output flux (range)

Up to 21,100lm Up to 151lm/W

Up to 32,100lm Up to 153lm/W

Typical luminaire output flux (range)

Up to 10,000lm Up to 161lm/W

Up to 30,400lm Up to 162lm/W

Up to 60,900lm

LM/W Up to 162lm/W Power consumption Up to 63W Up to 190W Up to 375W Colour temperature 3000K / 4000K CRI 70 / 80 Nominal voltage 220-400V / 120-277V / 347-480V / 50-60Hz Ta Up to 50°C CxS Up to 0.392 In-rush current 55A 110A 140A

LM/W

Up to 140W

Up to 210W

Power consumption

4000K / 5700K

Colour temperature

CRI

80

Nominal voltage

220-240V / 50-60Hz

Ta

Up to 50°C

In-rush current

65A

1

1 HT

2

1

2

3

C

B

330mm 330mm 400mm

A

390mm 492mm 622mm

A

124mm 338mm 136mm

B

B

77mm 77mm 90mm

B

A

330mm 330mm 400mm 4.5kg 5.6kg 6.8kg

C

321mm 421mm 521mm 5.6kg 8.8kg 16.8kg

C

A/C

KG

KG

56

57

Product overview The ideal solutions for your sports environments

58

59

A few of our projects

Cape Town (South Africa) - Product: OMNIBLAST-E

MTK Stadium - Budapest (Hungary) - Product: OMNIBLAST GEN2

Avenches (Switzerland) - Product: OMNIBLAST GEN2

60

Laval (Canada) - Product: OMNISTAR

Aegerten (Switzerland) - Product: OMNIBLAST GEN2

Avenches (Switzerland) - Product: OMNISTAR

61

A few of our projects

Palais des Sports - Besançon (France) - Product: OMNIBLAST GEN2

Pan American Games - Lima (Peru) - Product: OMNISTAR

Alcochete (Portugal) - Product: INDU BAY GEN3

62

Sint-Truiden (Belgium) - Product: HID

Montegranaro (Italy) - Product: INDU BAY GEN3

Portet-sur-Garonne (France) - Product: OMNIBLAST GEN2

63

A few of our projects

Réunion Island (France) - Product: OMNISTAR

Green Point Athletics Stadium - Cape Town (South Africa) - OMNIBLAST-E

64

UAS_Olympic stadium (1)

Ans (Belgium) - Product: OMNISTAR

Biscay (Spain) - Product: OMNISTAR

Kyiv (Ukraine) - Product: OMNIBLAST GEN2

65

www.schreder.com

Copyright © Schréder S.A. 2021 - Executive Publisher: Stéphane Halleux - Schréder S.A. - rue de Mons 3 - B-4000 Liège (Belgium) - The information, descriptions and illustrations herein are of only an indicative nature. Schréder gives no assurance that information, data or descriptions herein are accurate, reliable, complete, up-to-date, merchantable or fit for purpose, and expressly excludes any guarantee, representation or liability (whether implied, express or statutory) in connection therewith. Due to advanced developments, we may be required to alter the characteristics of our products without notice. As these may present different characteristics according to the requirements of individual countries, we invite you to consult us.

Page 1 Page 2 Page 3 Page 4 Page 5 Page 6 Page 7 Page 8 Page 9 Page 10 Page 11 Page 12 Page 13 Page 14 Page 15 Page 16 Page 17 Page 18 Page 19 Page 20 Page 21 Page 22 Page 23 Page 24 Page 25 Page 26 Page 27 Page 28 Page 29 Page 30 Page 31 Page 32 Page 33 Page 34 Page 35 Page 36 Page 37 Page 38 Page 39 Page 40 Page 41 Page 42 Page 43 Page 44 Page 45 Page 46 Page 47 Page 48 Page 49 Page 50 Page 51 Page 52 Page 53 Page 54 Page 55 Page 56 Page 57 Page 58 Page 59 Page 60 Page 61 Page 62 Page 63 Page 64 Page 65 Page 66

www.schreder.com

Powered by