Schréder: správné sportovní osvětlení, které splňuje národní a mezinárodní normy, zaručuje bezpečnost, viditelnost a pohodlí a zároveň omezuje světelné znečištění, aby se zachovala tmavá obloha a dobré vztahy s komunitou.
Sports lighting designs The right light, where, when and how it is needed
Content
04
Key facts and figures
06
06 08
Regulations and standards
Regulations and standards
Your benefits
Schréder solutions for sports facilities
10
12
Footbal l field
10
Outdoor tennis court
18
26 30 36 42 46 50 38
Indoor tennis court
Schréder solutions for your sports facilities
Multi-sports hall
Multi-sports ground
Padel court
Swimming pool
Rugby field
Other sports
A few of our projects
60
52 54
Control solutions
Product overview
A few of our projects 60
2
Cédric Collard Schréder Sports Segment Manager
Our society is evolving and our habits are changing. We are more and more connected and remote working is become more common. But moving and breathing is what makes us human and keep us fit. Physical activity is important and is recommended by the World Health Organisation. It is the best natural way to keep your body and your mind in shape. By practising a sport I can challenge myself and socialise while playing with family, friends and new acquaintances. It helps clear the head and keep the mind sharp so we can succeed in our challenges. Players, whether they play for fun or as a professional, wherever they play, indoor or outdoor and whenever they play, during the day or after work, deserve to do so in the best conditions. LED technology has sufficiently evolved to deliver energy-efficient sports lighting that limits light spill and pollution. Sports lighting can also entertain, creating a fun and exciting atmosphere. A well-designed sports lighting solution will also guarantee sharp, vivid images to capture nice moments on TV when our favourite team is scoring or on our phones when our kids are playing. Staying connected with our body, mind and society in the digital era
3
Key facts and figures The trend is here; grab it or leave it!
72 %
75 %
37.1
Average number of hours an employee works - this represents 7.42 hours per day
Percentage of EU population living in urban areas
Percentage of EU population practicing sports outside working hours
Cost per year, for a population of 10 million people, when half of the population is insufficiently active € 910,000,000
55 %
Number of persons employed in the sports sector in Europe 1,694,100
Average energy savings by replacing HID fixtures with LED floodlights
4
5
Regulations and standards EN 12193 for sports lighting The European committee for standardisation has established a norm for sports lighting applications: the European Standard EN 12193. Its purpose is to enable a good quality sports lighting through recommendations and requirements. For each application, the norm defines:
The minimum level of illuminance (E average in lux [lx]) • Maximise visual perception The minimum level of light uniformity (U 0 ) • Maximise visual comfort The maximum level of glare (GR or R G ) • Minimise discomfort The minimum colour rendering index (CRI or R a ) • Maximise real colour perception
How does it work? For each sport
Areas definition • Principal area (playing area needed for the performance of a certain sport) • Total area (additional safety area outside the principal area) Grid points definition • For measurements and calculations • To ensure that light performances are respected Class definition • Class I = top-level competition (international, national, top level training) • Class II = mid-level competition (regional, local, high level training) • Class III = low-level competition (local, small club, training, school sports)
6
7
Your benefits Best partner for retrofits , new installations and maintenance
Sports clubs
Cities
Energy savings High-quality facilities (attract new members and sponsors) Control solution and data monitoring Generate revenue (extend opening hours, more time spent in the bar & restaurant) Improve branding
Promote healthy and active lifestyles Sustainability, dark sky protection, and light pollution minimised Welcoming space Dynamic image Reduced cost of ownership
Players
Installers
Safety and high visual comfort when playing Boost interactions and atmosphere Improve the experience Heighten emotions Flexibility to play day and night
Easy & fast installation Safe set-up Simple planning and maintenance Futureproof (trouble-free upgrades & software updates) Compliant with regulations and certifications
8
Schréder expertise and LED technology for outstanding sports lighting
RETURN ON INVESTMENT
Low light pollution Avoid disturbing the neighbourhood Dark sky compliant Protect our skies, nature and animals 7 R&D offices around the world Always developing cutting-edge technologies Schréder process Enjoy a personalised service from the audit to the installation and the commissioning SUSTAINABILITY & RELIABILITY
COMFORT
High quantity of light Up to 240,000 lumen per floodlight to enjoy every detail of the game High uniformity Minimum of 70% to avoid dark zones Low glare Maximum of 55 to not disturb players and spectators during the game Instant light Control the luminaires physically via a power switch or remotely via a wireless control system
Low energy consumption Up to 75% energy savings compared with HID lighting power consumption Huge lifetime Above 50,000 hours = 34 years if the luminaires operate 4h per day Versatile control solutions The right light where, when and how it is needed
9
Schréder solutions for sports facilities
12
Football field
18 26
Outdoor tennis court
Indoor tennis court
30
Multi-sports hall
36 38 42 46 50
Multi-sports ground
Padel court
Swimming pool
Rugby field
Other sports
10
s
11
Football field
12
Masts in the corners (before the sideline) Football lighting solutions
105m
Principal area: 105x68m
EN12193 Class I
EN12193 Class II
EN12193 Class III
Grid points: 21x13 = 273pt Number of masts: 4 Masts location: x: 14m / y: -4m Maintenance factor: 0.9
200lx
75lx
ILLUMINANCE 500lx
UNIFORMITY
0.7
0.6
0.5
GLARE
55
55
55
CRI
70
60
60
13
Football field
SOLUTION CLASS I COMPLIANT
1
Nominal values
HID
Professional 500lux – 200lux – 75lux Mast height: 18m
106kW
Illuminance
506lx
Uniformity
0.77
500lux 99%
50% energy saved
53kW
GR
<55
ECOBLAST 6
CRI
70
200lux 40%
80% energy saved
Total power
53,120W
21kW
Total number of floodlights
32
75lux 15%
8kW
92% energy saved
Floodlights per pole
8
Initial flux
236,100lm
Colour temperature
OMNIBLAST GEN2
Other configuration
4000K
Power
1,660W
• technical versatility
SOLUTION CLASS II COMPLIANT
2
Nominal values
HID
Semi-professional 200lux – 100lux – 75lux Mast height: 18m
44kW
Illuminance
211lx
Uniformity
0.80
200lux 95%
43% energy saved
25kW
GR
<55
ECOBLAST 6
CRI
70
100lux 47%
73% energy saved
Total power
26,560W
12kW
Total number of floodlights
16
75lux 36%
10kW
77% energy saved
Floodlights per pole
4
Initial flux
236,100lm
OMNISTAR
Colour temperature
OMNIBLAST GEN2
Other configurations
4000K
Power
1,660W
• technical versatility
• specific
mountings
14
SOLUTION CLASS III COMPLIANT Amateur 100lux – 75lux Mast height: 18m
3
Nominal values
HID
24kW
Illuminance
107lx
Uniformity
0.74
100lux 93%
50% energy saved
12kW
GR
<55
ECOBLAST 6
CRI
70
75lux 70%
63% energy saved
Total power
13,280W
9kW
Total number of floodlights
8
Floodlights per pole
2
Initial flux
236,100lm
OMNISTAR
Colour temperature
OMNIBLAST GEN2
Other configurations
4000K
Power
1,660W
• technical versatility
• specific
mountings
SOLUTION CLASS III COMPLIANT Amateur 75lux Mast height: 18m
4
Nominal values
HID
18kW
Illuminance
88lx
Uniformity
0.74
75lux 85%
50% energy saved
9kW
GR
<55
ECOBLAST 5
CRI
70
Total power
11,080W
Total number of floodlights
8
Floodlights per pole
2
Initial flux
196,800lm
OMNISTAR
Colour temperature
OMNIBLAST GEN2
Other configurations
4000K
Power
1,385W
• technical versatility
• specific
mountings
15
Football field
Masts in the corners (behind the sideline) Football lighting solutions
105m
Principal area: 105x68m
EN12193 Class I
EN12193 Class II
EN12193 Class III
Grid points: 21x13 = 273pt Number of masts: 4 Masts location: x: -6.5m / y: -4m Maintenance factor: 0.9
200lx
75lx
ILLUMINANCE 500lx
UNIFORMITY
0.7
0.6
0.5
GLARE
55
55
55
CRI
70
60
60
16
SOLUTION CLASS I COMPLIANT
5
Nominal values
HID
Professional 500lux – 200lux – 75lux Mast height: 25m
106kW
Illuminance
507lx
Uniformity
0.89
500lux 99%
42% energy saved
62kW
GR
<55
ECOBLAST 6
CRI
70
200lux 39%
76% energy saved
Total power
63,100W
25kW
Total number of floodlights
40
75lux 15%
9kW
92% energy saved
Floodlights per pole
10
Initial flux
236,100lm
OMNIBLAST GEN2
Other configuration
Colour temperature
4000K
Power
1,660W
• technical versatility
SOLUTION CLASS II COMPLIANT
6
Nominal values
HID
Semi-professional 200lux – 100lux – 75lux Mast height: 25m
44kW
Illuminance
223lx
Uniformity
0.83
200lux 90%
32% energy saved
30kW
GR
<55
ECOBLAST 6
CRI
70
100lux 45%
66% energy saved
Total power
33,200W
15kW
Total number of floodlights
20
75lux 34%
11kW
75% energy saved
Floodlights per pole
5
Initial flux
236,100lm
OMNISTAR
Colour temperature
OMNIBLAST GEN2
Other configurations
4000K
Power
1,660W
• technical versatility
• specific
mountings
17
Outdoor tennis court
18
Masts in the corners (before the baseline) Outdoor tennis lighting solutions
23.77m
Principal area: 30x15m Grid points: 13x7 = 91pt Number of masts: 4 Masts location: x: 4m / y: -4m Maintenance factor: 0.9
EN12193 Class I
EN12193 Class II
EN12193 Class III
300lx
200lx
ILLUMINANCE 500lx
UNIFORMITY
0.7
0.7
0.6
GLARE
50
50
55
CRI
70
60
60
19
Outdoor tennis court SOLUTION CLASS I COMPLIANT
1
Nominal values
HID
Professional 500lux – 300lux – 200lux Mast height: 8m
12,320W
Illuminance
530lx
Uniformity
0.80
500lux 94%
71% energy saved
3,609W
GR
<50
INDU FLOOD GEN2 3
CRI
70
300lux 57%
82% energy saved
Total power
3,840W
2,189W
Total number of floodlights
12
200lux 38%
1,459W
88% energy saved
Floodlights per pole
3
Initial flux
58,000lm
OMNISTAR
Colour temperature
OMNIFLOOD
Other configurations
4000K
Power
320W
• technical versatility
• specific
mountings • remote driver
SOLUTION CLASS II COMPLIANT Semi-professional 300lux – 200lux Mast height: 8m
2
Nominal values
HID
4,480W
Illuminance
354lx
Uniformity
0.79
300lux 85%
51% energy saved
2,176W
GR
<50
INDU FLOOD GEN2 3
CRI
70
200lux 56%
68% energy saved
Total power
2,560W
1,433W
Total number of floodlights
8
Floodlights per pole
2
Initial flux
58,000lm
OMNISTAR
OMNIFLOOD
Other configurations
Colour temperature
4000K
Power
320W
• technical versatility
• specific
mountings • remote driver
20
21
Outdoor tennis court
Masts in the corners (behind the baseline) Outdoor tennis lighting solutions
23.77m
Principal area: 30x15m Grid points: 13x7 = 91pt Number of masts: 4 Masts location: x: -6m / y: -4m Maintenance factor: 0.9
EN12193 Class I
EN12193 Class II
EN12193 Class III
300lx
200lx
ILLUMINANCE 500lx
UNIFORMITY
0.7
0.7
0.6
GLARE
50
50
55
CRI
70
60
60
22
SOLUTION CLASS I COMPLIANT
3
Nominal values
HID
Professional 500lux – 300lux – 200lux Mast height: 10m
12,320W
Illuminance
507lx
Uniformity
0.82
500lux 99%
54% energy saved
5,683W
GR
<50
ECOBLAST 6
CRI
70
300lux 59%
73% energy saved
Total power
5,740W
3,387W
Total number of floodlights
4
200lux 39%
2,239W
82% energy saved
Floodlights per pole
1
Initial flux
215,200lm
OMNISTAR
INDUFLOOD GEN2
Other configurations
Colour temperature
4000K
• specific
• higher
Power
1,435W
mountings
lumen/watt
SOLUTION CLASS II COMPLIANT Semi-professional 300lux – 200lux Mast height: 10m
4
Nominal values
HID
4,480W
Illuminance
312lx
Uniformity
0.77
300lux 96%
18% energy saved
3,686W
GR
<50
INDU FLOOD GEN2 3
CRI
70
200lux 64%
45% energy saved
Total power
3,840W
2,458W
Total number of floodlights
12
Floodlights per pole
3
Initial flux
58,000lm
OMNISTAR
OMNIFLOOD
Other configurations
Colour temperature
4000K
Power
320W
• technical versatility
• specific
mountings • remote driver
23
Outdoor tennis court
Masts in the corners (behind the baseline) Outdoor tennis lighting solutions
32.5m
Principal area: 30x15m Grid points: 13x7 = 91pt Number of masts: 4 Masts location: x: 4m / y: -4m Maintenance factor: 0.9
EN12193 Class I
EN12193 Class II
EN12193 Class III
300lx
200lx
ILLUMINANCE 500lx
UNIFORMITY
0.7
0.7
0.6
GLARE
50
50
55
CRI
70
60
60
24
SOLUTION CLASS II COMPLIANT Semi-professional 300lux – 200lux Mast height: 12m
5
Nominal values
HID
10,350W
Illuminance
304lx
Uniformity
0.72
300lux 99%
57% energy saved
4,455W
GR
<50
INDU FLOOD GEN2 3
CRI
70
200lux 66%
71% energy saved
Total power
4,500W
2,970W
Total number of floodlights
12
Floodlights per pole
3
Initial flux
69,600lm
OMNISTAR
OMNIFLOOD
Other configurations
Colour temperature
4000K
Power
375W
• technical versatility
• specific
mountings • remote driver
SOLUTION CLASS III COMPLIANT Amateur 200lux Mast height: 12m
6
Nominal values
HID
5,360W
Illuminance
202lx
Uniformity
0.72
200lux 99%
45% energy saved
2,970W
GR
<55
INDU FLOOD GEN2 3
CRI
70
Total power
3,000W
Total number of floodlights
8
Floodlights per pole
2
Initial flux
69,600lm
OMNISTAR
OMNIFLOOD
Other configurations
Colour temperature
4000K
Power
375W
• technical versatility
• specific
mountings • remote driver
25
Indoor tennis court
26
Bilateral implantation Indoor tennis lighting solutions
23.77m
Principal area: 30x15m Grid points: 13x7 = 91pt Implantation: Bilateral Lateral distance between floodlights and tennis court: 3.5m Floodlights tilt: 5° Maintenance factor: 0.9
EN12193 Class I
EN12193 Class II
EN12193 Class III
500lx
300lx
ILLUMINANCE 750lx
UNIFORMITY
0.7
0.7
0.5
GLARE
35
40
40
CRI
80
60
60
27
Indoor tennis court SOLUTION CLASS I COMPLIANT
1
Nominal values
HID
Professional 750lux – 500lux – 300lux Installation height: 7m
9,240W
Illuminance
789lx
Uniformity
0.76
750lux 95%
49% energy saved
4,739W
GR
<35
INDU FLOOD GEN2 3
CRI
80
500lux 63%
66% energy saved
Total power
4,988W
3,142W
Total number of floodlights
14
300lux 38%
1,895W
79% energy saved
Floodlights per side
7
Initial flux
65,300lm
OMNISTAR
Colour temperature
Other configuration
4000K
Power
375W
• specific
mountings • remote driver
SOLUTION CLASS II COMPLIANT
2
Nominal values
HID
Semi-professional 500lux – 300lux – 200lux Installation height: 7m
6,160W
Illuminance
504lx
Uniformity
0.76
500lux 99%
52% energy saved
2,970W
GR
<40
INDU FLOOD GEN2 3
CRI
70
300lux 60%
71% energy saved
Total power
3,000W
1,800W
Total number of floodlights
8
Floodlights per side
4
Initial flux
69,600lm
OMNISTAR
Other configuration
Colour temperature
4000K
Power
375W
• specific
mountings • remote driver
28
SOLUTION CLASS III COMPLIANT
3
Nominal values
HID
Amateur 300lux – 200lux Installation height: 7m
3,700W
Illuminance
312lx
Uniformity
0.79
300lux 96%
50% energy saved
1,843W
GR
<40
INDU FLOOD GEN2 3
CRI
70
Total power
1,920W
Total number of floodlights
6
Floodlights per side
3
Initial flux
58,000lm
OMNISTAR
Colour temperature
Other configuration
4000K
Power
320W
• specific
mountings • remote driver
29
Multi-sports hall
30
Bilateral implantation Multi-sports hall lighting solutions
40m
Principal area: 40x20m
Grid points: 15x7 = 105pt Implantation: Bilateral Lateral distance between floodlights and field: 1m Floodlights tilt: 20° Maintenance factor: 0.9
EN12193 Class I
EN12193 Class II
EN12193 Class III
500lx
200lx
ILLUMINANCE 750lx
UNIFORMITY
0.7
0.7
0.5
GLARE
35
40
40
CRI
80
60
60
31
Multi-sports hall SOLUTION CLASS I COMPLIANT
1
Nominal values
HID
Professional 750lux – 500lux – 200lux Installation height: 7m
29,250W
Illuminance
772lx
Uniformity
0.73
750lux 97%
70% energy saved
8,730W
GR
<35
INDU FLOOD GEN2 3
CRI
80
500lux 65%
80% energy saved
Total power
9,000W
5,850W
Total number of floodlights
24
200lux 26%
2,340W
92% energy saved
Floodlights per side
12
Initial flux
65,300lm
OMNISTAR
Colour temperature
Other configuration
4000K
Power
375W
• specific
mountings • remote driver
SOLUTION CLASS II COMPLIANT
2
Nominal values
HID
Semi-professional 500lux – 300lux – 200lux Installation height: 7m
19,500W
Illuminance
514lx
Uniformity
0.84
500lux 97%
70% energy saved
5,820W
GR
<40
INDU FLOOD GEN2 3
CRI
70
300lux 58%
Total power
6,000W
82% energy saved
3,480W
Total number of floodlights
16
200lux 39%
88% energy saved
2,340W
Floodlights per side
8
Initial flux
69,600lm
OMNISTAR
Other configuration
Colour temperature
4000K
Power
375W
• specific
mountings • remote driver
32
SOLUTION CLASS III COMPLIANT
3
Nominal values
HID
Amateur 300lux – 200lux Installation height: 7m
11,700W
Illuminance
313lx
Uniformity
0.76
300lux 96%
69% energy saved
3,600W
GR
<40
INDU FLOOD GEN2 3
CRI
70
200lux 64%
79% energy saved
Total power
3,750W
2,400W
Total number of floodlights
10
Floodlights per side
5
Initial flux
69,600lm
OMNISTAR
Colour temperature
Other configuration
4000K
Power
375W
• specific
mountings • remote driver
SOLUTION CLASS III COMPLIANT
4
Nominal values
HID
Amateur 200lux Installation height: 7m
7,800W
Illuminance
207lx
Uniformity
0.80
200lux 97%
68% energy saved
2,483W
GR
<40
INDU FLOOD GEN2 3
CRI
70
Total power
2,560W
Total number of floodlights
8
Floodlights per side
4
Initial flux
58,000lm
OMNISTAR
Other configuration
Colour temperature
4000K
Power
320W
• specific
mountings • remote driver
33
Multi-sports hall
Industrial implantation Multi-sports hall lighting solutions
40m
Principal area: 40x20m
EN12193 Class I
EN12193 Class II
EN12193 Class III
Grid points: 15x7 = 105pt Implantation: Industrial Maintenance factor: 0.9
500lx
200lx
ILLUMINANCE 750lx
UNIFORMITY
0.7
0.7
0.5
GLARE
35
40
40
CRI
80
60
60
34
SOLUTION CLASS II COMPLIANT
5
Nominal values
HID
Semi-professional 500lux – 300lux – 200lux Installation height: 8m
19,500W
Illuminance
558lx
Uniformity
0.87
500lux 90%
77% energy saved
4,554W
GR
<40
INDU BAY GEN3 1
CRI
80
300lux 54%
86% energy saved
Total power
5,060W
2,732W
Total number of high- bays
44
200lux 36%
1,822W
91% energy saved
High-bays implantation
11x4
Initial flux
18,700lm
Colour temperature
4000K
Power
115W
SOLUTION CLASS III COMPLIANT
6
Nominal values
HID
Amateur 200lux Installation height: 8m
7,800W
Illuminance
236lx
Uniformity
0.75
200lux 85%
75% energy saved
1,955W
GR
<40
INDU BAY GEN3 1
CRI
80
Total power
2,300W
Total number of high- bays
20
High-bays implantation
5x4
Initial flux
18,700lm
Colour temperature
4000K
Power
115W
35
Multi-sports ground
Masts in the corners (before the baseline) Multi-sports ground lighting solutions
40m
Principal area: 40x20m
EN12193 Class I
EN12193 Class II
EN12193 Class III
Grid points: 15x7 = 105pt Number of masts: 4 Masts location: x: 8m / y: -3m Maintenance factor: 0.9
200lx
75lx
ILLUMINANCE 500lx
UNIFORMITY
0.7
0.6
0.5
GLARE
55
55
55
CRI
70
60
60
36
SOLUTION CLASS II COMPLIANT Semi-professional 200lux – 75lux Mast height: 8m
7
Nominal values
HID
6,380W
Illuminance
238lx
Uniformity
0.69
200lux 84%
61% energy saved
2,520W
GR
<55
INDU FLOOD GEN2 3
CRI
70
75lux 32%
85% energy saved
Total power
3,000W
960W
Total number of floodlights
8
Floodlights per pole
2
Initial flux
69,600lm
OMNISTAR
OMNIFLOOD
Other configurations
Colour temperature
4000K
Power
375W
• technical versatility
• specific
mountings • remote driver
SOLUTION CLASS III COMPLIANT Amateur 75lux Mast height: 8m
8
Nominal values
HID
3,520W
Illuminance
85lx
Uniformity
0.67
75lux 88%
75% energy saved
880W
GR
<55
INDU FLOOD GEN2 3
CRI
70
Total power
1,000W
Total number of floodlights
4
Floodlights per pole
1
Initial flux
46,400lm
OMNISTAR
OMNIFLOOD
Other configurations
Colour temperature
4000K
Power
250W
• technical versatility
• specific
mountings • remote driver
37
Padel court
38
Masts on / outside the cage Padel lighting solutions
Principal area: 20x10m Grid points: 13x7 = 91pt Number of masts: 4 Masts location: x: 4m / y: 0m Maintenance factor: 0.9
EN12193 Class I
EN12193 Class II
EN12193 Class III
Indoor
EN12193 Class I
EN12193 Class II
EN12193 Class III
Outdoor
500lx
300lx
ILLUMINANCE 750lx
300lx
200lx
ILLUMINANCE 500lx
UNIFORMITY
0.7
0.7
0.5
UNIFORMITY
0.7
0.7
0.6
GLARE
35
40
40
GLARE
50
50
55
CRI
80
60
60
CRI
70
60
60
39
Padel court SOLUTION
1
CLASS I (INDOOR)
Nominal values
HID
Professional 750lux – 500lux – 300lux Mast height: 6m
5,700W
Illuminance
797lx
Uniformity
0.76
750lux 94%
58% energy saved
2,406W
GR
<35
INDU FLOOD GEN2 3
CRI
80
500lux 63%
72% energy saved
Total power
2,560W
1,613W
Total number of floodlights
8
300lux 38%
973W
83% energy saved
Floodlights per pole
2
Initial flux
54,400lm
OMNISTAR
Colour temperature
OMNIFLOOD
Other configurations
4000K
Power
320W
• technical versatility
• specific
mountings • remote driver
SOLUTION
2
CLASS II (INDOOR) CLASS I (OUTDOOR)
Nominal values
HID
Pro & semi-pro 500lux – 300lux – 200lux Mast height: 6m
3,900W
Illuminance
635lx
Uniformity
0.78
500lux 79%
59% energy saved
1,580W
GR
<40
INDU FLOOD GEN2 3
CRI
70
300lux 47%
76% energy saved
Total power
940W
2,000W
Total number of floodlights
8
200lux 31%
620W
84% energy saved
Floodlights per pole
2
Initial flux
46,400lm
OMNISTAR
OMNIFLOOD
Other configurations
Colour temperature
4000K
Power
250W
• technical versatility
• specific
mountings • remote driver
40
SOLUTION
3
CLASS III (INDOOR) CLASS II (OUTDOOR)
Nominal values
HID
Semi-pro & amateur 300lux – 200lux Mast height: 6m
2,000W
Illuminance
318lx
Uniformity
0.78
300lux 94%
53% energy saved
940W
GR
<40
INDU FLOOD GEN2 3
CRI
70
200lux 63%
69% energy saved
Total power
1,000W
630W
Total number of floodlights
4
Floodlights per pole
1
Initial flux
46,400lm
OMNIFLOOD
Other configuration
Colour temperature
4000K
Power
250W
• technical versatility
SOLUTION CLASS III (OUTDOOR) Amateur 200lux Mast height: 6m
4
Nominal values
HID
1,400W
Illuminance
247lx
Uniformity
0.77
200lux 81%
56% energy saved
616W
GR
<55
INDU FLOOD GEN2 3
CRI
70
Total power
760W
Total number of floodlights
4
Floodlights per pole
1
Initial flux
34,800lm
OMNIFLOOD
Other configuration
Colour temperature
4000K
Power
190W
• technical versatility
41
Swimming pool
42
Bilateral implantation Swimming pool lighting solutions
Principal area: 25x15m Grid points: 13x7 = 91pt Implantation: Bilateral Lateral distance between floodlights and pool: 2m Maintenance factor: 0.9
EN12193 Class I
EN12193 Class II
EN12193 Class III
300lx
200lx
ILLUMINANCE 500lx
UNIFORMITY
0.7
0.7
0.5
GLARE
35
40
40
CRI
80
60
60
43
Swimming pool SOLUTION CLASS I COMPLIANT
1
Nominal values
HID
Professional 500lux – 300lux – 200lux Installation height: 7m
6,400W
Illuminance
572lx
Uniformity
0.75
500lux 87%
49% energy saved
3,263W
GR
<35
INDU FLOOD GEN2 3
CRI
80
300lux 52%
70% energy saved
Total power
3,750W
1,950W
Total number of floodlights
10
200lux 35%
1,313W
79% energy saved
Floodlights per side
5
Initial flux
65,300lm
OMNISTAR
Colour temperature
Other configuration
4000K
Power
375W
• specific
mountings • Remote driver
SOLUTION CLASS II COMPLIANT
2
Nominal values
HID
Semi-professional 300lux – 200lux Installation height: 7m
3,900W
Illuminance
313lx
Uniformity
0.79
300lux 96%
51% energy saved
1,920W
GR
<40
INDU FLOOD GEN2 3
CRI
70
200lux 64%
67% energy saved
Total power
1,280W
2,000W
Total number of floodlights
8
Floodlights per side
4
Initial flux
46,400lm
OMNISTAR
Other configuration
Colour temperature
4000K
Power
250W
• specific
mountings • Remote driver
44
SOLUTION CLASS III COMPLIANT
3
Nominal values
HID
Amateur 200lux Installation height: 7m
2,600W
Illuminance
217lx
Uniformity
0.88
200lux 92%
47% energy saved
1,380W
GR
<40
INDU FLOOD GEN2 3
CRI
70
Total power
1,500W
Total number of floodlights
6
Floodlights per side
3
Initial flux
46,400lm
OMNISTAR
Colour temperature
Other configuration
4000K
Power
250W
• specific
mountings • Remote driver
45
Rugby field
46
Masts in the corners (before the dead ball line) Rugby lighting solutions
120m
Principal area: 120x70m
EN12193 Class I
EN12193 Class II
EN12193 Class III
Grid points: 23x11 = 253pt Number of masts: 4 Masts location: x: 14m / y: -4m Maintenance factor: 0.9
200lx
75lx
ILLUMINANCE 500lx
UNIFORMITY
0.7
0.6
0.5
GLARE
55
55
55
CRI
70
60
60
47
Rugby field SOLUTION CLASS I COMPLIANT
1
Nominal values
HID
Professional 500lux – 200lux – 75lux Mast height: 18m
125kW
Illuminance
502lx
Uniformity
0.74
500lux 100%
52% energy saved
60kW
GR
<55
ECOBLAST 6
CRI
70
200lux 40%
81% energy saved
Total power
59,760W
24kW
Total number of floodlights
36
75lux 15%
9kW
93% energy saved
Floodlights per pole
9
Initial flux
236,100lm
Colour temperature
OMNIBLAST GEN2
Other configuration
4000K
Power
1,660W
• technical versatility
SOLUTION CLASS II COMPLIANT
2
Nominal values
HID
Semi-professional 200lux – 100lux – 75lux Mast height: 18m
52kW
Illuminance
201lx
Uniformity
0.78
200lux 100%
50% energy saved
26kW
GR
<55
ECOBLAST 6
CRI
70
100lux 50%
75% energy saved
Total power
26,560W
13kW
Total number of floodlights
16
75lux 37%
10kW
81% energy saved
Floodlights per pole
4
Initial flux
236,100lm
OMNISTAR
Colour temperature
OMNIBLAST GEN2
Other configurations
4000K
Power
1,660W
• technical versatility
• specific
mountings
48
SOLUTION CLASS III COMPLIANT Amateur 75lux Mast height: 18m
3
Nominal values
HID
28kW
Illuminance
82lx
Uniformity
0.70
75lux 91%
64% energy saved
10kW
GR
<55
ECOBLAST 5
CRI
70
Total power
11,080W
Total number of floodlights
8
Floodlights per pole
2
Initial flux
196,800lm
OMNISTAR
Colour temperature
OMNIBLAST GEN2
Other configurations
4000K
Power
1,385W
• technical versatility
• specific
mountings
49
Other sports
Golf
Stadium
Table tennis
BMX
50
Ice Hockey
Athleticism
Firing range
Hockey
51
Control solutions The right light, where , when and how it is needed
Schréder ITERRA
Schréder provides a full range of intelligent control solutions to ensure comfort and an effective energy management. This includes dimming, scheduling, monitoring and the creation of dynamic lighting scenarios to entertain fans. All of our floodlights and luminaires are designed to be controlled wirelessly or via cables in outdoor and indoor environments.
52
Schréder ITERRA
BASIC
CORE
ACTIVE
Flexible, easy & straightforward
V
V
V
Cost-effective
V
V
V
Increased lifetime of luminaires
V
V
V
Easy to install
V
V
V
Easy to manage
V
V
V
Easy to monitor
V
V
V
Scalable & futureproof
V
V
V
Open standards & protocols
V
V
V
Wireless • DALI Bluetooth (BLE5.0 mesh network – up to 200m or Gateway) • DMX
V
V
V
Wired • DALI • DMX
V
V
V
Software trigger
V
V
V
Manual trigger
V
V
V
Scheduling and sensors
V
V
SMS control
V
V
Physical box with code/token
V
V
Complex integration (≠ type of field, outdoor + indoor, wired + wireless)
V
V
Data monitoring
V
V
V
Cloud access
V
V
V
Secured protocols
V
V
V
Dimming
V
V
V
Scenes creation
V
V
V
Custom request
V
V
Entertainment & show
V
RGBW
V
Colour temperature
V
Music synchronisation
V
53
Product overview
1 - 10V DAL I OR DMX
DAL I OR DMX
GLASS IK 09
PC IK 10
IK 08
IP 66
IP 66
ECOBLAST
OMNIBLAST GEN2 OMNIBLAST GEN2 is the ideal tool for sports venues and other large area applications that require a lighting solution with the highest efficiency and flexibility to adapt to the different lighting needs.
ECOBLAST is a new innovative modular floodlight that has been designed to offer an outstanding combination of performance and flexibility for lighting sports venues where high lumen packages and a perfect control of light are needed.
3
4
5
6
1
2
3
Typical luminaire output flux (range)
Typical luminaire output flux (range)
Up to 104,700lm
Up to 139,600lm
Up to 174,500lm
Up to 209,400lm
Up to 64,800lm Up to 105lm/W
Up to 129,700lm Up to 108lm/W
Up to 194,600lm Up to 105lm/W
LM/W
Up to 113lm/W
LM/W
Up to 1,240W
Up to 1,550W
Up to 1,850W
Power consumption Up to 930W
Up to 1,202W
Up to 1,856W
Up to 618W
Power consumption
3000K / 4000K / 5700K
Colour temperature
3000K / 4000K / 5700K
Colour temperature
CRI
70 / 80 / 90
CRI
70 / 80 / 90
Nominal voltage
220-400V / 277V / 347V / 50-60Hz
Nominal voltage
220-400V / 120-277V / 347-480V / 50-60Hz
Ta
Up to 45°C
Ta
Up to 55°C
CxS
Up to 0.297
CxS
Up to 0.554
In-rush current
5A
In-rush current
5A
A
A
C
C
C
C
B
B
A
A
B
B
A
3
4 5
6
1
2
3
C
A 696 mm B 583mm 765mm C 360mm 346mm
595mm 700mm
A
B
188mm 630mm
B
C
A
250mm 520mm 790mm 12kg 28kg 35kg
C
C
*
19kg 24kg 28kg 31kg
54
KG
KG
A
B
B
*Weight without driver
IP 66
IK 08
IP 66
IK 08
OMNIFLOOD
OMNISTAR
OMNIFLOOD is the ideal versatile tool to replace floodlights equipped with traditional discharge lamps of 50 to 400W
OMNISTAR is a versatile LED floodlight that provides a beneficial replacement for a full range of HID lighting fixtures in a variety of indoor and outdoor sports applications.
1
3
MONO
Typical luminaire output flux (range)
Up to 5,300lm
Up to 25,100lm
Typical luminaire output flux (range)
Up to 67,800lm
LM/W
Up to 122lm/W Up to 135lm/W
LM/W
Up to 160lm/W
Up to 53W
Up to 227W
Power consumption
Power consumption
Up to 532W
3000K / 4000K
Colour temperature
Colour temperature
3000K / 4000K / 5700K
CRI
70
CRI
70 / 80 / 90
Nominal voltage
220-240V / 50-60Hz
Nominal voltage
220-400V / 120-277V / 347-480V / 50-60Hz
Up to 55°C
Ta
Ta
Up to 55°C
CxS
Up to 0.349
CxS
Up to 0.260
In-rush current
170A
In-rush current
150A
1
3
B
A
532mm
A
500mm 546mm
A
C
80mm
B
72mm 88mm
B
C
530mm 14kg
C
311mm 475mm 9kg 18.4kg
C
A
KG
KG
B
55
Product overview
GLASS IK 08
PC IK 10
IP 66
IK 09
IP 66
INDU BAY GEN3 With the 3 rd generation INDU BAY GEN3, Schréder offers the leading luminaire for high-bay environments with a minimised total cost of ownership.
INDU FLOOD GEN2 INDU FLOOD GEN2 is an innovative floodlight that combines outstanding lumen output and low consumption. Schréder provides here the leading luminaire in terms of lumen per watt.
1
2
1
2
3
Typical luminaire output flux (range)
Up to 21,100lm Up to 151lm/W
Up to 32,100lm Up to 153lm/W
Typical luminaire output flux (range)
Up to 10,000lm Up to 161lm/W
Up to 30,400lm Up to 162lm/W
Up to 60,900lm
LM/W Up to 162lm/W Power consumption Up to 63W Up to 190W Up to 375W Colour temperature 3000K / 4000K CRI 70 / 80 Nominal voltage 220-400V / 120-277V / 347-480V / 50-60Hz Ta Up to 50°C CxS Up to 0.392 In-rush current 55A 110A 140A
LM/W
Up to 140W
Up to 210W
Power consumption
4000K / 5700K
Colour temperature
CRI
80
Nominal voltage
220-240V / 50-60Hz
Ta
Up to 50°C
In-rush current
65A
1
1 HT
2
1
2
3
C
B
330mm 330mm 400mm
A
390mm 492mm 622mm
A
124mm 338mm 136mm
B
B
77mm 77mm 90mm
B
A
330mm 330mm 400mm 4.5kg 5.6kg 6.8kg
C
321mm 421mm 521mm 5.6kg 8.8kg 16.8kg
C
A/C
KG
KG
56
57
Product overview The ideal solutions for your sports environments
58
59
A few of our projects
Cape Town (South Africa) - Product: OMNIBLAST-E
MTK Stadium - Budapest (Hungary) - Product: OMNIBLAST GEN2
Avenches (Switzerland) - Product: OMNIBLAST GEN2
60
Laval (Canada) - Product: OMNISTAR
Aegerten (Switzerland) - Product: OMNIBLAST GEN2
Avenches (Switzerland) - Product: OMNISTAR
61
A few of our projects
Palais des Sports - Besançon (France) - Product: OMNIBLAST GEN2
Pan American Games - Lima (Peru) - Product: OMNISTAR
Alcochete (Portugal) - Product: INDU BAY GEN3
62
Sint-Truiden (Belgium) - Product: HID
Montegranaro (Italy) - Product: INDU BAY GEN3
Portet-sur-Garonne (France) - Product: OMNIBLAST GEN2
63
A few of our projects
Réunion Island (France) - Product: OMNISTAR
Green Point Athletics Stadium - Cape Town (South Africa) - OMNIBLAST-E
64
UAS_Olympic stadium (1)
Ans (Belgium) - Product: OMNISTAR
Biscay (Spain) - Product: OMNISTAR
Kyiv (Ukraine) - Product: OMNIBLAST GEN2
65
www.schreder.com
Copyright © Schréder S.A. 2021 - Executive Publisher: Stéphane Halleux - Schréder S.A. - rue de Mons 3 - B-4000 Liège (Belgium) - The information, descriptions and illustrations herein are of only an indicative nature. Schréder gives no assurance that information, data or descriptions herein are accurate, reliable, complete, up-to-date, merchantable or fit for purpose, and expressly excludes any guarantee, representation or liability (whether implied, express or statutory) in connection therewith. Due to advanced developments, we may be required to alter the characteristics of our products without notice. As these may present different characteristics according to the requirements of individual countries, we invite you to consult us.
Page 1 Page 2 Page 3 Page 4 Page 5 Page 6 Page 7 Page 8 Page 9 Page 10 Page 11 Page 12 Page 13 Page 14 Page 15 Page 16 Page 17 Page 18 Page 19 Page 20 Page 21 Page 22 Page 23 Page 24 Page 25 Page 26 Page 27 Page 28 Page 29 Page 30 Page 31 Page 32 Page 33 Page 34 Page 35 Page 36 Page 37 Page 38 Page 39 Page 40 Page 41 Page 42 Page 43 Page 44 Page 45 Page 46 Page 47 Page 48 Page 49 Page 50 Page 51 Page 52 Page 53 Page 54 Page 55 Page 56 Page 57 Page 58 Page 59 Page 60 Page 61 Page 62 Page 63 Page 64 Page 65 Page 66Powered by FlippingBook