BEKA Schréder - Smart and sustainable lighting solutions

Case Study: Highmast installation 400W HID replacement

The LEDFLOOD-MAXI provides a 39% energy saving compared to a 400W high-intensity discharge luminaire, whilst fully meeting the application light level requirements. Comparing a 400W HID to a LE DFLOOD-MAXI highmast installation in a coal mine

Specifications Number of units per highmast: 9 Pole height: 30m

Luminaire fitted with 400W High-Pressure Sodium Lamp

LEDFLOOD-MAXI 160 LED

Energy Savings

400W HPS/T

LEDFLOOD- MAXI

Luminaire power consumption

432W

265W

Maintenance factor

0.75

0.8

39% Energy Savings (*)

18.95lux

18.83lux

Eh ave

100%

5.8lux

5.8lux

E min

61%

23 850W

38 880W

Total power consumption (W)

265W

432W

Total cost of ownership (TCO) over 10 years based on R1.83/kWh

R2 683 345

R3 580 620

(*) Optic 5356, optimised design based on specifications

Detail on lighting design comparison available on request.