BEKA Schréder - Smart and sustainable lighting solutions

Key advantages

• Manufactured in South Africa • Cost-effective and efficient solution to maximise energy and maintenance savings • Marine grade, high-pressure die-cast aluminium housing • Designed to easily upgrade or replace the surge protection device, LEDs or drivers • Designed to meet international sport federation lighting regulations • Flexibility: modular approach for high-power applications (one-to-one replacement for up to 2000W HID lamps) • Compliant with UHD/HD/4K broadcast and super slow motion replays (flicker-free) • Instant switch on/off (static) - dynamic optional setting to create dramatic or theatrical effects • Inclination angle adjustable on-site • Surge protection 10kV/10kA • Meeting Dark Sky requirements by using accessories such as vertical louvres and hoods • Available in Zone 2 and 21/22 versions (MIDI only) • 5-year warranty (Terms and conditions apply)

1-E MIDI

2-E MIDI

3-E MIDI

1-E MAXI

2-E MAXI

3-E MAXI

Characteristics

GENERAL INFORMATION Testing standard

SANS 60598, SANS 62262, SANS 475

Housing Protector

Marine grade high-pressure die-cast aluminium (EN 1706 AC-44300)

High-impact clear glass

MAXI only: High-impact UV-resistant polycarbonate (optional)

Housing finish

Unpainted aluminium

Aerodynamic resistance (CxS) (up to) 0.445m 2 Nominal voltage

198-264V – 50Hz

Surge protection

10kV / 10kA

20kV / 20kA (optional)

Operating temperature range (Ta)

-20°C to +40°C

OMNIBLAST

1-E MIDI

2-E MIDI

3-E MIDI

1-E MAXI

2-E MAXI

3-E MAXI

Wattage (up to)

390W

778W

1,170W

605W

1,211W

1,815W

Nominal flux (up to)

64,891lm 129,782lm 194,674lm 89,307lm 178,615lm 267,922lm 55,806lm 111,613lm 167,420lm 76,804lm 153,609lm 230,413lm 143lm/W 143lm/W 143lm/W 127lm/W 127lm/W 127lm/W

Luminaire output flux (up to) Luminaire efficacy (up to)

CONTROL

Colour temperature

4000K (Neutral white 740); 5700K (Cool white 757) CRI ≥70

DMX

Lifetime of the LEDs @Tq 25°C Lifetime of the Driver @Tq 25°C

100,000h - Up to L95B10

For project details

Up to 100,000h ≤10% failure rate

CIRCLE LIGHT

STADIUM

UNIVERSITY TRACK & FIELD

GOLF COURSE

AREA

INDUSTRIAL HARBOUR

HIGHMAST LIGHTING

INTERCHANGE

BRIDGE

IK 10 Up to

20kV Up to

402

403

IP 66

Please consult your sales representative for more information.