Characteristics
Performance
GENERAL INFORMATION Recommended installation height
ELECTRICAL INFORMATION Electrical class
Power consumption (W)
Nominal efficacy (lm/W)
Luminaire output flux (lm)
Luminaire efficacy (lm/W)
Photometry
Nominal flux (lm) (*)
4m to 6m
EU class I
Nominal voltage
198-264V – 50Hz
Driver included
Yes
Driver Current (mA)
Power factor
> 95% at full load
Number of LEDs
Line Current (A)
Luminaire
Typical
Typical
Typical
Typical
Typical
ROHS compliant
Yes
Surge protection
10kV / 10kA
Testing standard
SANS 60598
Electromagnetic compatibility (EMC)
SANS 55015:2013/A1:2015, SANS 61000-3-2:2014, SANS 61000-3- 3:2013, SANS 61547:2009, SANS 62493:2015 DALI 1-10V Integrated Movement & Daylight Sensor
160
400
0.34
13223
78
169
12562
160
Weight (kg)
LEDTEC : 6 LEDTEC Emergency Version: 7
160
550
0.48
17777
110
162
16888
154
4010
LEDTEC R : 13.7 LEDTEC S: 11.2
Control options
160
700
0.63
21967
144
153
20869
145
Standard mounting
LEDTEC : Surface mount LEDTEC R: Recessed LEDTEC S: Surface mount
160
900
0.51
18346
116
158
16878
145
4010
OPTICAL INFORMATION LED colour temperature 5700K (Cool white 757) Colour rendering index (CRI) ≥ 70
192
840
0.57
20774
132
158
19112
145
HOUSING AND FINISH Housing
LEDTEC: Marine grade high-pressure die-cast aluminium (EN 1706 AC-44300) LEDTEC R: Optical housing: Marine grade high-pressure
160
500
0.45
15483
105
148
13408
128
4010
160
700
0.62
20754
142
146
17973
126
OPERATING CONDITIONS Operating temperature range (Ta)
-30°C up to +40°C
13223 / 923 (EM) 17777 / 923 (EM) 21967 / 923 (EM)
160
400
0.34
78
169
12562
160
die-cast aluminium (EN 1706 AC-44300)
LIFETIME OF THE LEDS @ TQ 25°C For all versions
160
550
0.48
110
162
16888
154
4010
Gear housing and fixation bracket: Marine grade e-coated and epoxy powder coated sheet metal LEDTEC S: Optical, gear housing and fixation bracket: Marine grade e-coated and epoxy powder coated sheet metal
100,000h - L70B10
160
700
0.63
144
153
20869
145
LIFETIME OF THE DRIVER @ TQ 25°C For all versions
Tolerance on LED flux is ± 7% and on total luminaire power ± 5% (*) The nominal flux is an indicative LED flux @ Ts 85°C based on LED manufacturer’s data. The real flux output of the luminaire depends on environmental conditions (e.g. temperature and pollution) and the optical efficiency of luminaire. The type of LED used is subject to change due to the ongoing rapid progress taking place in LED technology.
100,000h ≤10% failure rate
Protector
Glass High-impact polycarbonate (optional)
Housing finish
White (RAL 9003), Brilliant finish
Light Distribution
Tightness level
IP 66
Impact resistance Glass: IK 08 Polycarbonate: IK 10 Access for maintenance Easy access to the gear compartment
4010 optic
250 150 50
cd/klm
90
60
30
0
0°/180°
90°/270°
90°
0°
180°
270°
380
381