BEKA Schréder - Smart and sustainable lighting solutions

Case Study: 70W HPS Comparison

Comparing a 70W HPS to a PICOLUM 1 streetlight installation

Specifications Road: B1 classified road + 1.5m setback

The PICOLUM 1 provides a 78% energy saving compared to a 70W high-pressure sodium luminaire, while fully meeting the road light level requirements. Furthermore, a much better colour rendering index is provided, thereby enhancing the safety and visibility of pedestrians and road users.

Luminaire spacing: 40m Road width: 7m + 2*2m sidewalks Height: 7m

Luminaire fitted with 70W High-Pressure Sodium Lamp

PICOLUM 1 24 LED

Luminaire power consumption

85W

32W

Spacing between luminaires

23m

40m

Energy Savings

Average illuminance sidewalk left

9.1lx

8lx

70W HPS/E

PICOLUM 1

Minimum sidewalk left

6.2lx

2.4lx

Average illuminance lanes

8.3lx

6.7lx

100%

78% Energy Savings (*)

Minimum illuminance lanes

5.5lx

3.4lx

Semi-cylindrical illuminance

5.1lx

3.9lx

Average illuminance sidewalk right

5.1lx

5.1lx

Minimum sidewalk right

3.7lx

2.6lx

22% 32W

85W

800W

Power consumption per km

3696W

(*) Optic 5305, optimised design based on specifications. Additional savings can be generated by integrating Schréder EXEDRA smart control systems.

78%

Percentage saving per km

Design Criteria - 5lx (Eh), 1.5lx (Emin), 2lx (ESCmin) Using PICOLUM 32W OPTIC 5305 at 7m HM with no outreach, 0° rake, 1.5m setback and 40m spacing in order to achieve the design criteria above

Please note: Detail on lighting design comparison available on request.

Chintsa East, South Africa

134

135

Powered by