HYBRID DRIVER 1 STEP-INSTALLATION INSTRUCTION 07042025

Schréder Australia Pty Ltd Bldg 4A, Parklands Estate, 21-23 South Street, Rydalmere, NSW 2116, Australia T: 1300 489 780 | ABN 17 604 331 937 www.sylvania-schreder.com

Wiring Diagram for RAPTOR 4/3/2 and SPORTSLINE 1200W and BRITELINE LED G2/1

LED Driver

LED Luminaire

(Note 6)

IMPORTANT!! Refer to next page for luminaire terminal connections.

(Refer to Note 3)

Driver Output cable 2 core+earth 450/750V or 0.6/1KV TPS or Circular cable is suitable. Note the maximum length in the table below.

(Note 7)

Maximum Cable Length Between Driver and Luminaire Table

Briteline LED G2/1

Max load LED

Raptor 4/3/2

(680V)

Length(M) Length(M) 100 Max 200 Max 320 Max 480 Max 500 Max 1000 Max 1600 Max 2400 Max

Cable Size Length(M) 1.5mm2 1000 Max 2.5mm2 2000 Max

- Dim

PH2 (N)

PH1

- + O/P

+

3200 Max 4800 Max

4.0mm2 6.0mm2

(Note 4 & 5)

S1 (Note 2) C

376-440 V (216-253V) Input Range

(Note 1)

Must be wired in accordance with the Australian standard Wiring Rules

376-440 V : For 415V Driver 216-253 V : For 240V Driver Notes 1: 2: Dim cable must be sheathed and be rated for the same or higher voltage as the supply cables. The dim signal requirement at the drivers dim terminals is a maximum current draw of 3mA and be within a voltage range of 9 to 13.2Vdc. 3: The luminaire terminal box must be wired as per the appropriate wiring diagram in the installation instructions to match the luminaire being used. Each luminaire that the Hybrid Driver can be used with requires a luminaire specific wiring arrangement. Three link wires are supplied with each driver however the number of links used depends on the luminaire wiring requirement. Incorrect wiring may cause damage to driver and/or luminaire. If a two wire Hybrid driver is being used with luminaires that were previously wired to drivers that required additional wires, consult Schreder for guidance. 4: To maintain optimum surge withstand capability, the input, output and dim cables ideally should be segregated as much as possible. A distance of even 10mm is adequate. If multiple drivers are located in the same pole or cabinet, it is acceptable to cable tie or group all of the outputs together but separated from the inputs which also can be grouped. Secure cables to terminal block mounting bracket on BUILT-IN model. 5: Secure cables to terminal block mounting bracket on BUILT-IN model. 6: Lift points on BUILT-IN drivers are to be used as an aid to installation not permanent suspension. Use only appropriately rated lifting attachments. Do not lift driver over personnel or body parts. 7: Din rail may be attached using four off M5 screws. Do not cover vent slots.

PAGE 3 OF 13

Document Version 2025-04

Rev: 2.3

Powered by