they apply to the Warranty component.
Inrush Current Codes: HYB1ST240V, HYB1ST415V, HYB1ST240VIP65, HYB1ST415VIP65, HYB1ST240V060, HYB1ST415V060, HYB1ST240VIP65060, HYB1ST415V060
240V (Nominal Mains) I peak = 59A Duration @ 50% of peak 5ms 415V (Nominal Mains) I peak = 42.5A Duration @ 50% of peak 5ms Earth Leakage Current - 0.2mA per unit
Breaker Recommendations 240V DRIVER 415V DRIVER
MCB Rating (A)
1 pole
2 Pole
16 20 25 32 40
1 1 2 2 3
1 2 2 3 4
1 2 2 3 4
3 3 4 6 7
The Drivers are not user repairable. Under no circumstances should any covers on the IP20 driver be removed to access internal components. For IP65 drivers, only the single M8 latch bolt on the main enclosure should be loosened to access the main terminal block. The small diecast box on top of the IP65 driver should not be opened and has tamper proof seals over the lid screw heads. If covers are removed performance could be adversely affected and warranty may be voided. If checking and testing is required, it should only be undertaken by suitably qualified persons and under guidance from Sylvania Schréder technical staff. Fault finding information is available on request. The main supply should be isolated and locked out before accessing terminals or performing any work near the driver terminations. Although the drivers have various shutdown and protection systems, there may be a residual voltage at the output terminals for a period of time after the main supply has been isolated or after open circuit protection has been activated (less than 50V within 1 minute). The voltage at the output terminals should always be checked and if necessary, allow further time to decay before working on the driver terminations.
Maintenance and Repair